$ 4391.00Ex works
Equipped with a 7-inch touch controller, it supports 120 programs and 100 settings; Temperature range -40~ 150 ° C, humidity control 20~ 98% RH; multi-wing air supply circulation ensures uniform temperature and humidity, with perfect safety protection device.
Category : Temperature Humidity Chamber
Brand : Apkjgroup
SKU : NB042324
Service :The delivery and service By NBCLab.Com
APKJ AP-HX-50C programmable humidity chamber mainly provides complex high and low temperature alternating test environment and test conditions for the testing of electronic parts, industrial materials, finished product research and development, production, and inspection. The device adopts 7-inch super touch AP-900 intelligent programmable temperature and humidity controller, with 120 sets of programs and 100 segments per set of programming capabilities, and supports USB data export and RS232 communication functions.
1. Adopt 7-inch large touch AP-900 intelligent programmable temperature and humidity controller, support 120 sets of programs, each set of 100 segments of programming 2. Remote control can be achieved by connecting to the computer through the LAN interface 3. Utilize a multi-wing blower for strong air circulation to ensure uniform indoor temperature and humidity distribution 4. Equipped with complete safety protection devices, the status is automatically displayed in the event of a failure and troubleshooting methods are provided 5. Adopt original imported Compressor sets, including French Taikang and Japanese Hitachi brands 6. Studio volume 50L, Temperature range -40~ 150 ℃, Moisture control range 20~ 98% R.H
The equipment is mainly composed of a combination of control panel, switchboard, thermal insulation compartment, blower, heater, humidifier and freezer. The multi-wing blower is used to strongly circulate the air to avoid any dead ends and make the indoor temperature and humidity evenly distributed. The refrigeration system adopts the original imported Compressor, the 0 ℃~ -40 ℃ model adopts one-stage compression, and the -40 ℃~ -70 ℃ adopts binary cascade refrigeration.
Electronics Communication, Chemical, Hardware, Rubber, Toys, Scientific Research
GB/T10589-2008、GB/T10586-2006、GB/T10592-2008、GB/T2423.1-2008、GB/T2423.2-2008、GB/T2423.3-2006、MIL-STD810D、GB/T2423.4-2008、GJB150.9-1986、GB2423.34-2012、MIL-STD883C
1. Configure the corresponding capacity air or power switch 2. Connect the AC220V power supply, requiring single-phase two-wire + protective ground wire 3. Design programs through the controller or import existing programs 4. Set the program loop mode and end action 5. Start the equipment for testing 6. Export test data via USB interface
○ Prohibition of testing or storage of flammable, explosive or volatile matter specimens ○ Prohibition of testing or storage of samples of corrosive substances Prohibition of testing or storage of biological samples Prohibition of testing or storage of samples of strong electromagnetic emission sources ○ No strong vibration around the equipment, the ground is flat and well ventilated No strong electromagnetic field around the equipment, no flammable, explosive, corrosive substances and dust ○ Leave appropriate use and maintenance space around the equipment ○ power requirements: voltage range AC (220 +/- 10) V, frequency (50 +/- 0.5) Hz, protective ground resistance less than 4Ω
Recommend a programmable constant temperature and humidity test chamber. It features a 7-inch large touch screen controller, which is intuitive to operate and capable of setting complex temperature variation programs, making it suitable for simulating the harsh environments that electronic components may encounter in actual use. Its temperature range covers -40°C to 150°C, with a humidity range of 20% to 98% RH. It offers precise control over uniformity and fluctuation, ensuring the reliability of test results.
For testing chemical materials, the core focus is on the temperature and humidity control accuracy and stability of the equipment. It is recommended to pay attention to temperature uniformity (e.g., within ±2°C), humidity deviation (e.g., ±2% RH), as well as heating and cooling rates. This device adopts a multi-wing forced air circulation system to avoid testing dead zones and ensure uniform conditions inside the chamber. Additionally, it supports program linking and cycling, enabling precise reproduction of your set temperature and humidity change curves to meet testing requirements such as material aging and performance evaluation.
For long-term operation and remote monitoring, it is recommended to select models that support network communication and robust data management functions. Devices equipped with LAN or RS485 communication interfaces are preferred, as they can be directly connected to a computer for remote programming, data acquisition, and power control. It is also advisable for the controller to be capable of storing a large number of program groups and data, and to support exporting historical records via a USB drive. This not only facilitates real-time monitoring but also eases subsequent data analysis and report generation.