High Accuracy Electrochemical sensor, detection accuracy ≤ +/- 3%, Protection Rating IP65, built-in pump suction measurement supports more than 10 Meters sampling distance, and has 100,000 large-capacity Data storage functions.
Category : Gas Detector
Brand : GaoPin
SKU : NB042339
Service :The delivery and service By NBCLab.Com
The NGP40-CH2O Portable is a High Accuracy portable device for rapid detection of gas concentration, temperature and Humidity. It uses a 2.4 inch high definition color screen and a well-known brand Sensor. Based on electrochemistry, infrared, catalytic combustion, thermal conductivity, PID photoion and other detection principles, it can detect more than 1,000 gases. It is suitable for gas concentration detection in pipelines, confined spaces, atmospheric environments, and gas leakage or high concentration single gas purity analysis.
1. Waterproof splash, dustproof, explosion-proof, shockproof, intrinsically safe circuit design, anti-static, anti-electromagnetic interference, Protection Rating IP65, built-in water vapor dust Filter. 2. Built-in pump suction measurement, Response fast, sampling distance > 10 meters, special gas path design can measure negative pressure or positive pressure gas. 3.2.4-Inch high definition color screen displays real-time concentration, alarm, time, storage and other information, and the menu adopts simulation icons. 4. Large capacity Data storage, standard 100,000, support real-time, timing, alarm storage, data can be viewed and deleted locally or uploaded to computer analysis. 5. USB charging interface, compatible with a variety of charging methods, supports protection such as overcharge and overdischarge, and hot swapping. It can work during charging, and RS485 communication is optional. 6. Using 4500mA large capacity polymer battery, long battery life. 7. With multi-directional alarms such as sound and light, vibration, vision, under-voltage, fault, etc., alarm values and methods can be set. 8. High Accuracy Humidity measurement (optional), support temperature compensation, use Temperature range -40~ 70 ℃, can detect high temperature gas (optional). 9. It can detect 1 to 4 gases simultaneously, and the three display modes can be switched. 10. Chinese and English interface is optional, data recovery, zero point automatic tracking, target point three-level calibrating, calibrating misoperation prevention and other functions are complete. 11. Support real-time or regular detection, can record calibrated logs, maintenance logs, etc., with Sensor life reminder, fall alarm function.
The instrument uses electrochemistry, infrared, catalytic combustion, thermal conductivity, PID photoion and other principles of gas Sensor for detection. Through built-in pump sampling, the gas suction instrument, Sensor converts the gas concentration signal into an electrical signal, and then through professional circuit design and kernel algorithm processing, finally display the accurate concentration value on the screen, and trigger an alarm when the standard is exceeded.
Chemical, Petroleum, Environmental Protection Flue Gas Analysis, Pipeline, Boiler Gas Analysis, Air Treatment and other occasions that need to detect gas concentration
Exia II CT4 Ga
1. Turn on and check the power to ensure that the instrument has sufficient power. 2. According to the detection requirements, confirm whether the corresponding Sensor, sampling handle or Filter has been installed or selected. 3. Set the type of gas to be detected, the alarm value and the Alarm mode in the menu. 4. Place the sampling Probe in the area to be tested and start the pumping function for sampling detection. 5. Real-time observation of gas concentration, temperature Humidity and other data through 2.4-inch color screen. 6. If an alarm is triggered during the detection process, take corresponding measures according to prompts such as sound, light, and vibration. 7. After the test is completed, you can view and delete the historical data through the instrument, or connect to the computer through the USB interface, and use the host computer software to export and analyze the data. 8. After use, charge the instrument for next use.
● The instrument is intrinsically safe explosion-proof equipment with the explosion-proof mark Exia II CT4 Ga. Please use it in the specified dangerous place. ● Protection Rating is IP65, which can be dustproof and waterproof, but non-diving equipment, do not immerse in liquid. ● The built-in Filter needs to be checked and replaced regularly to prevent high Humidity or high dust environment from damaging the Sensor. ● Before selecting the high temperature sampling handle or pretreatment system, please confirm whether the gas temperature to be measured exceeds the default range of the instrument. ● Please use a matching or compatible charger when charging, and pay attention to whether the protection functions such as overcharge and overdischarge are normal. ● When calibrating, please follow the operating instructions strictly. The instrument has the function of automatic identification and prevention of calibrating misoperation. When not in use for a long time, it is recommended to charge it regularly to maintain battery activity. Do not perform dangerous operations with the instrument alarm function turned off. ● Pay attention to the life of the Sensor (2-3 years), pay attention to the lifespan expiration reminder of the instrument in time and replace it. ● When using the retractable sampling handle, pay attention to the integrity of the hose to avoid damage affecting the sampling.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.