Please contact customer service
Adopt 7-inch touch screen intelligent controller, support 120 sets of programs and data export. Temperature range -70~ 150 ℃, humidity control range 20~ 98% RH, equipped with multi-wing air supply circulation to ensure uniform temperature and humidity.
Category : Temperature Humidity Chamber
Brand : Apkjgroup
SKU : NB042342
Service :The delivery and service By NBCLab.Com
The programmable humidity chamber (model AP-HX-225F) mainly provides complex high and low temperature alternating test environment and test conditions for the testing of electronic parts, industrial materials, finished product research and development, production and inspection. The equipment adopts a 7-inch large touch AP-900 intelligent programmable temperature and humidity controller, with 120 sets of programs, each set of 100 segments of programming ability, and supports data recording and export.
1. Adopt a 7-inch large touch AP-900 intelligent programmable temperature and humidity controller, support 120 sets of programs, each set of 100 segments, and can set cycles, connections and final actions. 2. The controller can be connected to a computer through a LAN interface to enable remote programming, data collection, and device control. 3. Utilize a multi-wing blower for strong air circulation to ensure uniform indoor temperature and humidity distribution. 4. Equipped with complete safety protection devices, it automatically displays the fault status and provides troubleshooting methods when abnormal. 5. Adopt original imported high-efficiency Compressors (such as France Taikang, Japan Hitachi) and international brand core components (such as American Henry Oil, Denmark Danfoss Filter, etc.) to ensure stable and reliable performance. 6. The inner box is made of SUS304 stainless steel, the outer box is Cold rolled steel plate advanced baking paint, and the thermal insulation material is rigid polyurethane foam.
The equipment is mainly composed of a combination of control panel, switchboard, thermal insulation compartment, blower, heater, humidifier and freezer. The temperature and humidity conditions are set by a microcomputer program controller to drive the refrigeration system (using primary compression or binary cascade refrigeration), heating system and humidification system. The multi-wing blower is used for strong air circulation to achieve uniform and stable temperature and humidity in the test chamber to simulate the required test environment.
Electronics Communication, Chemical, Hardware, Rubber, Toys, Scientific Research
GB/T 10589-2008, GB/T 10586-2006, GB/T 10592-2008, GB/T 2423.1 - 2 008, GB/TT 2423.2 - 2 008, GB/T 2423.3 - 2 006 (IEC68-2-3), MIL-STD810D Method 502.2, GB/T 2423.4 - 2 008 (MIL-STD810) Method 507.2 Program 3, GJB150.9-1986, GB 2423.34 - 2 01 2, MIL-STD883C Method 1004.2
1. Ensure that the equipment is installed in a flat, well-ventilated site without strong vibration and strong electromagnetic field, and reserve maintenance space. 2. Connect an independent power supply that meets the requirements (AC220V, single-phase two-wire + protective ground wire). 3. Program editing and setting through a 7-inch touch controller or connected computer. 4. Place the sample in the box and observe the sample restrictions. 5. Start the device and run the set test program. 6. During the test, the data can be monitored by a controller or computer. 7. After the test, remove the sample and turn off the equipment as required.
• It is forbidden to test or store flammable, explosive, volatile matter, corrosive substances, biological samples, and samples of strong electromagnetic emission sources. • The installation site should be free from strong vibration, strong electromagnetic fields, flammable, explosive corrosive substances and dust. • An independent and compliant power supply (voltage AC220V +/- 10%, frequency 50 +/- 0.5Hz) must be configured, and the grounding resistance of the protective ground wire must be less than 4Ω. • Adequate maintenance and use space should be left around the equipment. • Note that the working environment temperature of the equipment is required to be 5~ 30 ° C. • Ventilated pipes, power cables, gas sources, water sources, etc. need to be prepared and installed by users separately.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.