$ 5857.00Ex works
Multi-wing air supply cycle to ensure uniform distribution of temperature and humidity, support 120 sets of program control and data export functions, Temperature Fluctuation +/- 0.5 ℃, humidity deviation +/- 2% R.H., with complete fault diagnosis and safety protection mechanism.
Category : Temperature Humidity Chamber
Brand : Apkjgroup
SKU : NB042343
Service :The delivery and service By NBCLab.Com
APKJ AP-HX-408A programmable humidity chamber is a professional Environmental performance equipment, which mainly provides complex high and low temperature alternating test environment and conditions for electronic parts, industrial materials, finished product research and development, production, inspection and other links. The equipment adopts 7-inch large touch AP-900 intelligent programmable temperature and humidity controller, supports 120 sets of programs and 100 segments of programming per set, suitable for Electronics Communication, Chemical, Hardware, Rubber, Toys, Scientific Research and other industries.
1. Adopt 7-inch large touch AP-900 intelligent programmable temperature and humidity controller, support 120 sets of programs, each set of 100 segments of programming, can set program cycle, connection and final action 2. With USB interface to connect to U disk to record test data in real time, export historical data and import pictures 3. Standard RS232 communication interface, optional RS485, supports remote computer control 4. The multi-wing blower has strong air circulation to ensure uniform indoor temperature and humidity distribution without dead ends 5. Complete safety protection device, automatically display the fault status and cut off the power when abnormal, and provide Troubleshooting method 6. Adopt original imported Compressor units (France Taikang or Japan Hitachi) and international brand core components to ensure efficient and stable operation
The equipment works together through the control panel, switchboard, thermal insulation compartment, blower, heater, humidifier, freezer and other components. The multi-wing blower is used to force air circulation, combined with the heating system and the refrigeration system (using primary compression or binary cascade refrigeration method), and the temperature and humidity in the working room are precisely adjusted by the microcomputer program controller to achieve the set constant temperature and humidity environment.
Electronics Communication, Chemical, Hardware, Rubber, Toys, Scientific Research
GB/T10589-2008、GB/T10586-2006、GB/T10592-2008、GB/T2423.1-2008、GB/TT2423.2-2008、GB/T2423.3-2006、MIL-STD810D、GB/T2423.4-2008、GJB150.9-1986、GB2423.34-2012、MIL-STD883C
1. Confirm that the installation site meets the requirements: no strong vibration, flat ground, well ventilated, no strong electromagnetic field and flammable and explosive substances 2. Connect AC220V power supply: single-phase two-wire + protective ground wire, voltage range (220 +/- 10) V, frequency (50 +/- 0.5) Hz 3. Design test programs through controllers or computers to set temperature, humidity parameters and cycle conditions 4. Place the sample on the studio grid rack and close the box door to ensure airtightness 5. Start the device to run tests, monitor data in real time, and export records via USB 6. After the test is completed, process it according to the end of the program and turn off the power of the device.
○ It is forbidden to test or store flammable, explosive, volatile matter, corrosive substances, biological samples, and strong electromagnetic emission source samples ○ The installation site needs no strong vibration, the ground is flat and ventilated, and there is no strong electromagnetic field influence ○ power requirements Independent configuration of air or power switch, protective ground wire grounding resistance is less than 4Ω ○ Appropriate use and maintenance space should be left around the equipment ○ The working environment temperature should be kept at 5~ 30 ℃, humidity ≤ 85% ○ Regularly check the Compressor high voltage protection, overcurrent and overheating protection and other safety devices ○ Note that the equipment does not contain ventilated pipes, power cables, gas sources, water sources and other external installation items
We recommend choosing the programmable constant temperature and humidity test chamber, as it can accurately simulate complex high-temperature and high-humidity environments, with a temperature range from 0 to 150°C and humidity control from 20% to 98% RH. It offers excellent uniformity, making it suitable for reliability testing of electronic components.
In scientific research, it is commonly used for material weathering tests and environmental simulation in new product development, such as verifying the performance changes of chemical materials or rubber products under different temperature and humidity conditions. This is because it complies with multiple national and military standards, ensuring the authority and reliability of the test results.
Quite important. A good controller, like the 7-inch touchscreen type, supports multiple programs and cycle settings, and can export data via USB, making it convenient for you to flexibly design testing processes. For example, when conducting combined temperature and humidity cycle tests, programming is simple, and data recording is hassle-free.