Please contact customer service
Adopt 7-inch touch screen controller, support 120 programs and USB data export; Temperature range -70~ 150 ℃, Humidity range 20~ 98% RH; Equipped with multi-wing air supply circulation to ensure uniform temperature and humidity, and have complete fault self-diagnosis and safety protection functions.
Category : Temperature Humidity Chamber
Brand : Apkjgroup
SKU : NB042347
Service :The delivery and service By NBCLab.Com
APKJ AP-HX-408F programmable humidity chamber is a kind of equipment used to provide complex high and low temperature alternating test environment. It mainly provides the required test conditions for electronic parts, industrial materials and finished products in R & D, production and inspection. It is suitable for Electronics Communication, Chemical, Hardware, Rubber, Toy, Scientific Research and other industries.
1. Equipped with a 7-inch large touch AP-900 intelligent programmable temperature and humidity controller, it supports 120 sets of programs, each set of 100 segments, can set program loops, connections and end actions, and has USB data recording and export functions. 2. The controller can be connected to the computer through the LAN interface to realize remote programming, data collection, recording, and equipment switching control. 3. The multi-wing blower is used for strong air supply circulation to ensure uniform distribution of temperature and humidity in the test chamber and avoid dead ends. 4. Equipped with complete safety protection devices, the controller screen automatically displays the fault status and provides troubleshooting methods when abnormal, and simultaneously cuts off the power supply. 5. The core refrigeration components are imported brands, such as France Taikang or Japan Hitachi Compressor, American Henry oil, Denmark Danfoss Filter and expansion valve, etc., to ensure the high efficiency and stability of the system. 6. Adopt binary cascade refrigeration (-40 ° C to -70 ° C models) to achieve a wide range of low temperature control. 7. The box door is sealed with double heat insulation to effectively prevent temperature leakage.
The test chamber precisely adjusts the working state of the refrigeration, heating, humidification and air circulation system through the control system to simulate the required temperature and humidity environment in a closed test space. The refrigeration system adopts Compressor refrigeration (0 ° C~ -40 ° C for primary compression, -40 ° C~ -70 ° C for cascade refrigeration), the heating system adopts nickel-chromium alloy heater, the humidification system increases the humidity in a specific way, and the multi-wing blower drives the air to circulate in the box to ensure the uniformity and Stability of the environment parameters. The microcomputer controller coordinates the operation of each system according to the preset program to achieve complex temperature and humidity changes. Linear dispersion.
Electronics Communication, Chemical, Hardware, Rubber, Toys, Scientific Research
GB/T10589-2008 Low temperature test chamber technical conditions, GB/T10586-2006 Damp heat testing chamber technical conditions, GB/T10592-2008 low/high temperature test chamber technical conditions, GB/T 2423.1 - 2008 Low temperature test Aa, Ab, GB/TT 2423.2 - 2008 Test B: High temperature test method, GB/T 2423.3 - 2006 (IEC68-2-3) constant humidity cabinet test Ca, MIL-STD810D method 502.2, GB/T 2423.4 - 2008 (MIL-STD810) method 507.2 Program 3, GJB150.9-1986 Military equipment environmental test method - humidity cabinet test, GB 2423.34 - 2012, MIL-STD883C method 1004.2 Temperature and humidity combined cycle test
1. Ensure that the equipment is installed in a site that meets the requirements (no strong vibration, flat ventilating, no strong electromagnetic field and corrosive substances), and reserve enough maintenance space. 2. Connect an independent power supply that meets the specifications (AC220V +/- 10%, 50Hz +/- 0.5Hz, and the protective ground resistance is less than 4Ω). 3. Turn on the main power switch. 4. Test program editing and setting through a 7-inch touchscreen controller or connected computer. 5. Put the sample into the box, noting that the sample must meet the equipment restrictions (flammable and explosive substances are prohibited). 6. Close the box door to ensure airtightness. 7. Start the controller and run the preset test program. 8. During the test, the data can be monitored by a controller or computer. 9. After the test, the equipment executes the final action according to the setting, and the sample is taken out after the environment in the box is restored to safety. 10. Power off the device.
This equipment is prohibited for flammable, explosive, volatile matter, corrosive substances, biological samples, strong electromagnetic emission source samples test or storage. The installation site needs to be free of strong vibration, the ground is flat, well ventilated, and there is no strong electromagnetic field, flammable and explosive corrosive substances and dust. Appropriate use and maintenance space must be left around the equipment. The power supply must use the corresponding capacity air or power switch independently configured, the power requirements are single-phase two-wire + protective ground, voltage AC (220 +/- 10) V, frequency (50 +/- 0.5) Hz, and the protective ground resistance must be less than 4Ω. The equipment does not include ventilated pipes, power cables, leakage switches, gas sources, water sources and other external environment installation items, which need to be prepared separately by the user. The working environment temperature is recommended to be between 5 and 30 ° C, the humidity is ≤ 85%, and the air pressure is within the normal atmospheric pressure range of 86kPa~ 106kPa. The weight of the equipment is 400kg, pay attention to safety when moving, and use the pulley and strong bolt equipped with the machine when fixing. When conducting low temperature tests, please pay attention to the working characteristics of the cascade refrigeration system (-40 ° C to -70 ° C models). Regularly check and ensure that the safety protection device (such as over-temperature protector, Compressor high voltage protection, overcurrent and overheating protection, etc.) functions normally.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.