Please contact customer service
Provide a wide temperature range from -70 ° C to 150 ° C and humidity control from 20% to 98% RH, using multi-wing air supply circulation to ensure uniform temperature and humidity. Equipped with a 7-inch touch screen controller, it supports 120 sets of programs and data export to meet a variety of standard testing requirements.
Category : Temperature Humidity Chamber
Brand : Apkjgroup
SKU : NB042352
Service :The delivery and service By NBCLab.Com
APKJ AP-HX-800F programmable humidity chamber is a test equipment with an Interior volume of 800L, which mainly provides complex high and low temperature alternating test environment and test conditions for the testing of electronic parts, industrial materials, finished product research and development, production, and inspection.
1. Equipped with a 7-inch large touch AP-900 intelligent programmable temperature and humidity controller, it supports 120 sets of programs, each set of 100 segments, can be set to cycle, connect and end actions, and has USB data recording and export and RS232 communication functions. 2. The controller can be connected to a computer via a LAN interface to enable remote programming, data collection, recording, and switch control. 3. Adopt a multi-wing blower for strong air circulation to ensure uniform indoor temperature and humidity distribution and avoid dead ends. 4. Equipped with complete safety protection devices, it automatically displays the fault status and provides troubleshooting methods in case of abnormality. 5, the use of high-quality core components, such as the original import of France Taikang or Japan Hitachi Compressor, the United States DuPont environmental refrigerant, Denmark Danfoss Filter and pressure switch, etc., to ensure stable and reliable performance. 6. The box door is air-tight with double heat insulation to effectively isolate temperature leakage; the window is equipped with an electric heater to prevent condensation.
The test chamber precisely adjusts the working state of the refrigeration system, heating system and humidification system through the control system. The refrigeration system adopts primary compression or binary cascade refrigeration (according to Temperature range), through the Compressor, condenser, evaporator and other components to achieve cooling and dehumidification; the heating system heats up through nickel-chromium heaters; the humidification system realizes humidity control. The air circulation system uses long-axis motors and wind turbines to force air supply, so that the temperature and humidity in the working room are evenly distributed, thereby simulating the set high and low temperature, heating and humidity test environment.
Electronics Communication, Chemical, Hardware, Rubber, Toys, Scientific Research
GB/T10589-2008、GB/T10586-2006、GB/T10592-2008、GB/T2423.1-2008、GB/T2423.2-2008、GB/T2423.3-2006、MIL-STD810D、GB/T2423.4-2008、GJB150.9-1986、GB2423.34-2012、MIL-STD883C
1. Ensure that the equipment is installed in a site that meets the requirements (no strong vibration, electromagnetic field, corrosion, well ventilated and sufficient maintenance space), and connect an independent power supply that meets the specifications (AC220V, single-phase two-wire + protective ground wire). 2. Turn on the main power switch and start the controller. 3. Design or call test programs through a 7-inch touchscreen controller or connected computer to set parameters such as temperature, humidity, and time. 4. Put the sample into the movable grid rack in the box and close the box door. 5. Start the test program, the device starts running, and data can be observed and recorded in real time through the window. 6. After the test is completed, the device executes the final action according to the preset program and removes the sample. 7. Power off the equipment and perform necessary maintenance.
This equipment is prohibited for testing or storing the following samples: flammable, explosive, volatile matter; corrosive substances; biological samples; strong electromagnetic emission source samples. Installation site requirements: the ground is flat, well ventilated; no strong vibration and strong electromagnetic field; no flammable, explosive, corrosive substances and dust around; reserve enough maintenance space. The power supply conditions must be strictly met: an independent air or power switch is configured; the voltage is AC (220 +/- 10) V; the frequency is (50 +/- 0.5) Hz; and the grounding resistance of the protective ground wire is less than 4Ω. The working environment temperature of the equipment is recommended to be 5~ 30 ° C, the humidity is ≤ 85%, and the air pressure is 86kPa~ 106kPa. Please note that the equipment standard plan does not include ventilated pipes, power cables, leakage switches, gas sources, water sources and other external environment installation items, which need to be prepared separately by the user. The equipment is equipped with multiple safety protections such as over-temperature protection, but the operator still needs to pay close attention to the operating status, and the fault alarm needs to be eliminated according to the prompts.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.