Please contact customer service
Adopt 7-inch intelligent touch controller, support 120 sets of programs and data export. Equipped with multi-wing air supply to ensure uniform temperature and humidity, built-in complete safety protection device. Temperature control accuracy of +/- 0.5 ℃, humidity deviation +/- 2% RH, to meet a number of national military standard test requirements.
Category : Temperature Humidity Chamber
Brand : Apkjgroup
SKU : NB042357
Service :The delivery and service By NBCLab.Com
APKJ AP-HX-1000F programmable humidity chamber is a kind of equipment used to provide complex high and low temperature alternating test environment. It mainly provides the required test conditions for electronic parts, industrial materials and finished products in R & D, production and inspection.
1. Adopt a 7-inch large touch AP-900 intelligent programmable temperature and humidity controller, support 120 sets of programs, each set of 100 segments, and can set cycles, connections and final actions. 2. The controller has a USB interface, which can be connected to a U disk to record and export data, and comes standard with an RS232 communication interface. 3. It can be connected to the computer through the LAN interface to realize remote programming, data collection, recording, and switch control. 4. Adopt a multi-wing blower with strong air circulation to ensure uniform indoor temperature and humidity distribution and avoid dead ends. 5. Equipped with complete safety protection devices, it automatically displays the fault status and provides troubleshooting methods when abnormal. 6. The refrigeration system adopts the original imported high-efficiency fully enclosed Compressor (such as French Taikang, Japanese Hitachi brand). 7. Key components adopt internationally renowned brands, such as American Henry Oil, Danish Danfoss Filter and Expansion Valve, American DuPont Environmental Refrigerant, etc., to ensure stable and reliable performance.
The test chamber is mainly composed of a combination of control panel, switchboard, thermal insulation compartment, blower, heater, humidifier, freezer, etc. The temperature and humidity program is set by a microcomputer program controller to drive the refrigeration system (using primary compression or binary cascade refrigeration), heating system and air circulation system to work together. The multi-wing blower is used to force the air in the domestic circulation of the box to distribute the temperature and humidity evenly, so as to achieve the set test environmental conditions.
Electronics Communication, Chemical, Hardware, Rubber, Toys, Scientific Research
GB/T 10589-2008, GB/T 10586-2006, GB/T 10592-2008, GB/T 2423.1 - 2 008, GB/T 2423.2 - 2 008, GB/T 2423.3 - 2 006 (IEC68-2-3), MIL-STD810D Method 502.2, GB/T 2423.4 - 2 008 (MIL-STD810) Method 507.2 Program 3, GJB150.9-1986, GB 2423.34 - 2 01 2, MIL-STD883C Method 1004.2
1. Ensure that the equipment is installed in a site that meets the requirements (no strong vibration, flat ventilating, no strong electromagnetic field, no flammable, explosive and corrosive substances), and reserve enough maintenance space. Connect the independent power supply that meets the requirements: single-phase two-wire + protective ground wire, voltage AC (220 +/- 10) V, frequency (50 +/- 0.5) Hz, protective ground wire grounding resistance less than 4Ω. 3. Turn on the main power switch and start the device. 4. Edit or call the test program through the 7-inch touch screen controller to set temperature and humidity parameters, cycle times, etc. 5. Place the sample in the box and observe the sample restrictions. 6. Start the test program and the device starts running. 7. During the test, the data can be monitored by a controller or a connected computer. 8. After the test, the device executes the final action according to the set program, takes out the sample and turns off the device power.
It is forbidden to use for testing or storage of flammable, explosive and volatile matter samples. It is prohibited to use it for testing or storing samples of corrosive substances. It is prohibited to use it for the testing or storage of biological samples. It is prohibited to use it for testing or storing samples of strong electromagnetic emission sources. The equipment installation site should be free of strong vibration, the ground should be flat and well ventilated. Equipment should be free from strong electromagnetic fields, flammable, explosive, corrosive substances, and dust. Appropriate use and maintenance space should be left around the equipment. The power supply needs to be equipped with an independent air or power switch of the corresponding capacity, and ensure that the grounding resistance is less than 4Ω. The recommended working environment temperature is 5~ 30 ℃, humidity ≤ 85%, and the air pressure is within the normal atmospheric pressure range of 86kPa~ 106kPa.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.