Using Three-Box structure, the test sample is still in the test area, and the temperature Impact is achieved by switching the strong cooling hot air circuit. Temperature range -65 ℃~ + 150 ℃, temperature recovery time ≤ 5 minutes, rapid conversion.
Category : Thermal Shock Test Chamber
Brand : Apkjgroup
SKU : NB042369
Service :The delivery and service By NBCLab.Com
APKJ 3AP-CJ-100C Thermal Shock Test Chamber is a device used to test the tolerance of materials in environments with rapid changes in extreme temperatures. It adopts Three-Box structure (high temperature zone, low temperature zone, test zone), and instantaneously introduces high or low temperature into the test zone through unique heat storage and cooling structure and forced air path switching. Thermal Shock testing is carried out on static samples, which is widely used in Electronics, Automotive, Metal, Chemical, National Defense Aerospace and other industries.
1. Using the Three-Box (high temperature zone, low temperature zone, test zone) structure, the test sample is completely stationary in the test zone, and the rapid temperature impact is achieved through the unique heat storage and cold storage structure and forced air circuit switching. 2. It can independently set three test conditions: high temperature, low temperature and Thermal Shock. When performing Impact, you can choose Dual-Box or Three-Box mode, and it has the function of high and low temperature testing machine. It can also perform normal temperature impact. 3. Equipped with the 7-inch large Touchscreen AP-950 programmable temperature controller independently developed by Aipei, it supports touch input, multi-temperature point setting, temperature alarm display and real-time temperature Linear dispersion display. 4. The box is made of rigid polyurethane foam insulation material, which has the advantages of energy saving, shock resistance and compression resistance, ultra-low temperature thermal conductivity, weather resistance and heat preservation, insulation and sound insulation, waterproof and moisture-proof. 5. Safety protection devices include Compressor multiple protection, laboratory temperature and door opening protection, power phase sequence phase loss protection, leakage circuit breaker, etc. 6. The refrigeration system adopts French Taikang or Japanese Hitachi fully enclosed low-noise rotor Compressor, with advanced Control mode, fast temperature recovery time (≤ 5min) and short conversion time (≤ 10s).
The equipment adopts heat storage and cold storage structure, which is divided into high temperature zone, low temperature zone and test zone. During the test, the temperature pre-accumulated in the high temperature zone or low temperature zone is quickly introduced into the test zone through the switching mode of strong refrigeration hot air circuit, and the static sample is continuously impacted at extremely high temperature and extremely low temperature to test the chemical or physical changes caused by thermal expansion and contraction of the material.
Electronics components, plastics, automation parts, communication components, auto parts, metals, chemical materials, plastics, defense industry, aerospace, military industry, BGA, PCB substrate, electronic chip IC, semiconductor ceramic, polymer materials
GB/T2423.1-2008、GB/T2423.2-2008、GB/T2423.22-2012、GJB150.5-86、GJB360.7-87、GJB367.2-87、QC/T17-92、EIA364-32、IEC68-2-14
1. According to the test requirements, set the high temperature, low temperature and Thermal Shock program on the 7-inch Touchscreen controller. 2. Place the sample on the sample shelf in the test area. 3. Select the desired Impact mode (Dual-Box or Three-Box). 4. Start the device, and the device will automatically execute the set temperature Impact program. 5. Monitor real-time temperature Linear dispersion and test status through the controller display. 6. After the test is completed, the device can automatically stop or execute subsequent setting procedures.
The equipment needs to be equipped with a corresponding capacity air or power switch for independent use by the user at the installation site. The power requirements are AC380V three-phase four-wire + protective ground wire, the voltage range is AC (380 +/- 10) V, Frequency (50 +/- 0.5) Hz, and the grounding resistance of the protective wire should be less than 4Ω. This plan does not include the installation of ventilated pipes, power supply (leakage switch), air source (air Compressor), water source (bottled water or water pipe) and other equipment environment items. Ambient Temperature should be maintained between + 25~ + 30 ℃, relative humidity ≤ 85%, pressure 86kPa~ 106kPa. When the equipment is not working, the Ambient Temperature should be kept at 0 ° C~ + 45 ° C; when the Ambient Temperature is lower than 0 ° C, the water retained in the equipment must be drained clean to prevent the pipeline from freezing and damage. Please be familiar with the names and functions of each part of the equipment before operation, including high greenhouse, laboratory, low greenhouse, operation board, Safety protection device, etc. Note that the maximum power of the device is about 10.0KW and the maximum current is about 15A to ensure that the power supply line meets the requirements.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.