Made of SUS304 stainless steel, the wall thickness of the Pressure Vessel is 2.5mm. Built-in oil-free vacuum pump, Vacuum Level can reach -0.09MPa or less, with pulsating vacuum and heating membrane double drying function. Equipped with High Accuracy gas filtrate device, effectively filter out particles larger than 0.22μm in diaMeter, and has a steam condensation system to achieve domestic circulation, no exhaust gas and waste water discharge.
Category : Autoclave / Sterilizer
Brand : SanShen
SKU : NB042589
Service :The delivery and service By NBCLab.Com
Vertical pulsating vacuum pressure steam Autoclave YMD65L uses saturated steam to sterilize the required items at high temperature and high voltage, which is widely used in environmental protection, university scientific research, food chemical and other units for sterilization.
1. SUS304 stainless steel material, Pressure Vessel wall thickness 2.5mm, large diameter vertical structure, radial self-expanding silicone sealing ring. 2. Dial rod 12-post latch synchronous telescopic primary switch structure, automatic vertical upward bounce when opening the lid, and the upper cover has heat insulation and anti-scalding protection. 3. Using electronic, mechanical, pressure, temperature chill down multiple safety chain protection devices, closed cover inspection system, the door is not closed properly equipment can not start, down to the set safe temperature and pressure will be unlocked, and there are open and close operation prompt tone. 4. The upper full-color 7-inch LCD screen can be used in Chinese and English, and the touch operation selects the sterilizing program and parameters. 5. Dynamic digital display pressure, temperature, time and alarm information, dynamic Linear dispersion display the whole process of operation, enter the status interface to check the current operation program, graphic display automatic sterilizing process. 6. Adopt three-level independent passwords and fingerprint recognition to control entry operations. 7. Built-in independent water tank and electric evaporator for easy sterilization room cleaning, water shortage alarm automatically cuts off the heating power supply. 8. Built-in steam condensation system, steam domestic circulation, pipeline closure without exhaust gas and wastewater discharge, to meet the needs of biosafety sterilization. 9. Equipped with High Accuracy Gas filtrating device, effectively filter out particles larger than 0.22um in diameter. 10. There is a wastewater sampling port, which is convenient for timely treatment of wastewater as required. 11. The sterilizing chamber has an external heating and insulation device, and the computer program can automatically adjust and control the heating temperature and time. 12. Equipped with Vacuum Level can reach oil-free vacuum pump below -0.09MPa, with pulsating vacuum and heating film double drying function. 13. Adopt low center of gravity, high load adjustable casters, and can be turned and shifted 360 °. 14. Design pressure 0.38MPa (temperature 150 ℃), sterilizing Temperature range 105~ 136 ℃, sterilizing time 0-65000min, pressure gauge range: -0.1~ 0.3MPa, double safety valve pressure over 0.24MPa automatic discharge steam. 15. Microcomputer automatic control, preset equipment, parcel, solution, rubber, medical waste and foster base six one-button selection of fixed sterilizing program and preheating, insulation, dissolve three auxiliary programs, preset program parameters can be modified according to demand, and custom programs can meet a variety of sterilizing needs. 16. There are two programs, DB test and vacuum test, used to test the equipment's vacuum leakage rate, exhaust capacity, and steam penetration rate. 17. The appointment timing start and warm-up function can automatically run according to the appointment setting time, and the appointment time is set from 0 to 9999min. 18. For non-liquid programs, preheating, pulsation, heating, sterilizing, exhaust, drying process automatic control, for liquid programs, preheating, heating, sterilizing, exhaust process automatic control. 19. Standard printer, can print sterilized temperature, time, pressure, FO value and other sterilized data in real time. Another USB interface can copy the sterilized data automatically recorded by the system to save the U disk. 20. Equipped with Pt100 temperature sensor, TT/PT test interface for multi-point temperature and pressure verification. 21. It has the function of viewing the current time, sterilizing times, failure time and code, and has the functions of plateau pressure, inner chamber pressure and inner chamber temperature compensation. 22. Pulsating cold air automatic discharge, sterilizing end steam automatic full row, micro row, no row or manual discharge can be selected. 23. Double fan cooling chilling down system, return valve to prevent negative pressure function. 24. Background safety test program, automatic fault detection system, over-temperature, overvoltage, leakage, overcurrent, short circuit, low water level and all kinds of fault beep sound and light alarm, LCD screen display alarm code and alarm information, sterilize program automatically stop. 25. Power-off memory storage function, sterilize the end of sound and light prompts and text display "can open the door", with a quick maintenance window.
The Autoclave uses saturated steam to sterilize items in a high temperature and high voltage environment. Through the microcomputer automatic Control system, the preheating, pulsation (non-liquid), heating, sterilizing, exhaust, drying (non-liquid) and other processes are automatically completed according to the preset program to achieve efficient and safe sterilization of items.
Environmental protection, university scientific research, food and chemical industry
Not mentioned
1. Enter the Operating interface through three-level independent password or fingerprint recognition. 2. Select the preset sterilizing program (instrument, parcel, solution, rubber, medical waste, foster base) or custom program on the 7-inch Touchscreen. 3. You can modify the preset program parameters or set custom programs according to your needs. 4. You can choose to use the appointment timing start and warm-up function. 5. Close the Autoclave door and close the lid inspection system to ensure that the door is properly closed. 6. Start the program and the equipment runs automatically. For non-liquid programs, the preheating, pulsation, heating, sterilizing, exhaust and drying processes are automatically completed; for liquid programs, the preheating, heating, sterilizing and exhaust processes are automatically completed. 7. After sterilizing, the sound and light of the device prompt and display "You can open the door", and you can choose the steam discharge method. 8. The sterilized data can be printed in real time through the printer, or the data can be copied to the U disk through the USB interface for storage.
• The device cannot start when the door is not closed properly. • The device needs to drop to the set safe temperature and pressure before unlocking the door. • When the equipment is short of water, it will alarm and automatically cut off the heating power supply. The double safety valve automatically discharges steam when the pressure exceeds 0.24MPa. • If overtemperature, overvoltage, leakage, overcurrent, short circuit, low water level and other faults occur during the operation of the sterilize program, the device will beep sound and light alarm, and the LCD screen will display the alarm information and automatically stop the program. • After sterilizing, you need to confirm that you can open the door according to the prompts before operating. • The equipment is equipped with a wastewater sampling port, and the wastewater needs to be treated in a timely manner as required.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.