Made of SUS304 stainless steel, Pressure Vessel wall thickness 2.5mm. Built-in steam condensation system to achieve domestic circulation of steam, no exhaust gas and wastewater effluent. Equipped with oil-free vacuum pump with Vacuum Level below -0.09MPa, with pulsating vacuum and heating film double drying function.
Category : Autoclave / Sterilizer
Brand : SanShen
SKU : NB042590
Service :The delivery and service By NBCLab.Com
Vertical pulsating vacuum pressure steam Autoclave YMMD85L uses saturated steam to sterilize items through high temperature and high voltage. The equipment is made of SUS304 stainless steel with a volume of 85L, which is widely used in environmental protection, university scientific research, food chemical and other units for sterilization.
1. SUS304 stainless steel material, Pressure Vessel wall thickness 2.5mm, large diameter vertical structure, radial self-expanding silicone sealing ring. 2. Dial rod 12-post latch synchronous telescopic primary switch structure, automatic vertical upward bounce when opening the lid, and the upper cover has heat insulation and anti-scalding protection. 3. Using electronic, mechanical, pressure, temperature chill down multiple safety chain protection devices, closed cover inspection system, the door is not closed properly equipment can not start, down to the set safe temperature and pressure will be unlocked, and there are open and close operation prompt tone. 4. The upper full-color 7-inch LCD screen can be used in Chinese and English, and the touch operation selects the sterilizing program and parameters. 5. Dynamic digital display pressure, temperature, time and alarm information, dynamic Linear dispersion display the whole process of operation, graphic display automatic sterilizing process. 6. Adopt three-level independent passwords and fingerprint recognition to control entry operations. 7. Built-in independent water tank and electric evaporator for easy sterilization room cleaning, water shortage alarm automatically cuts off the heating power supply. 8. Built-in steam condensation system, steam domestic circulation, pipeline closure without exhaust gas and wastewater discharge, to meet the needs of biosafety sterilization. 9. Equipped with High Accuracy Gas filtrating device, effectively filter out particles larger than 0.22um in diameter. 10. There is a wastewater sampling port, which is convenient for timely treatment of wastewater as required. 11. The sterilizing chamber has an external heating and insulation device, and the computer program can automatically adjust and control the heating temperature and time. 12. Equipped with Vacuum Level can reach oil-free vacuum pump below -0.09MPa, with pulsating vacuum and heating film double drying function. 13. Adopt low center of gravity, high load adjustable casters, and can be turned and shifted 360 °. 14. Microcomputer automatic control, preset equipment, parcel, solution, rubber, medical waste and foster base six one-button selection of fixed sterilizing program and preheating, insulation, dissolve three auxiliary programs, preset program parameters can be modified according to demand, and custom programs can meet a variety of sterilizing needs. 15. There are two programs, DB test and vacuum test, used to test the equipment's vacuum leakage rate, exhaust capacity, and steam penetration rate. 16. The appointment timing start and warm-up function can automatically run according to the appointment setting time, and the appointment time is set from 0 to 9999min. 17. For non-liquid programs, preheating, pulsation, heating, sterilizing, exhaust, drying process is fully automatic control, for liquid programs, preheating, heating, sterilizing, exhaust process is fully automatic control. 18. Standard printer, can print sterilized temperature, time, pressure, FO value and other sterilized data in real time. Another USB interface can copy the sterilized data automatically recorded by the system to save the U disk. 19. Equipped with Pt100 temperature sensor, TT/PT test interface for multi-point temperature and pressure verification. 20. It has the function of viewing the current time, sterilizing times, failure time and code, and has the functions of plateau pressure, inner chamber pressure and inner chamber temperature compensation. 21. The pulsating cold air is automatically discharged, and the steam at the end of sterilization is automatically discharged in full, micro, no or manual. 22. Double fan cooling chilling down system, return valve to prevent negative pressure function. 23. Background safety test program, fault automatic detection system, over temperature, overvoltage, leakage, overcurrent, short circuit, low water level and various fault beep sound and light alarm, LCD screen display alarm code and alarm information, sterilize program automatically stop. 24. Power-off memory storage function, sterilize the end of sound and light prompts and text display "can open the door", with a quick maintenance window.
The Autoclave uses saturated steam to sterilize the required items at high temperature and high voltage. It has a built-in steam condensation system to realize domestic circulation of steam, and the pipeline is closed without exhaust gas and waste water. The sterilizing process is fully automatically controlled by a microcomputer, and the steps of preheating, pulsation (non-liquid), heating up, sterilizing, exhaust, drying are automatically completed according to the preset program.
Environmental protection, university scientific research, food and chemical industry
The data did not mention specific compliance criteria.
1. Enter the Operating interface through three-level independent password or fingerprint recognition. 2. Select the preset sterilizing program (instrument, parcel, solution, rubber, medical waste, foster base) or custom program on the 7-inch LCD Touchscreen, and modify the parameters. 3. Close the Autoclave door, and the device's closed cover inspection system ensures that the door is closed and started. 4. The equipment runs automatically according to the selected program, completing the process of preheating, pulsating (non-liquid), heating up, sterilizing, exhausting, drying, etc. 5. At the end of sterilizing, the sound and light of the device prompt and display "You can open the door", and you can choose the steam discharge method (full row, micro row, no row or manual). 6. The sterilized data can be printed in real time through the standard printer, or the data can be copied to the U disk through the USB interface for storage.
• The device cannot be started without the door closed. The device will not unlock the door until it drops to the set safe temperature and pressure. • When there is a lack of water, it will alarm and automatically cut off the heating power supply. • Overtemperature, overvoltage, leakage, overcurrent, short circuit, low water level and other faults will trigger a buzzer sound and light alarm, the LCD screen displays the alarm code and information, and the sterilizing program automatically stops. • After sterilizing, you need to confirm that you can open the door according to the prompts before operating. • Wastewater can be treated in a timely manner as required through the wastewater sampling port.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.