Please contact customer service
Made of SUS304 stainless steel, the wall thickness of the Pressure Vessel is 2.5mm. The built-in steam condensation system realizes the domestic circulation of steam without exhaust gas and waste water. Equipped with oil-free vacuum pump with Vacuum Level below -0.09MPa, and has double drying function of pulsating vacuum and heating film.
Category : Autoclave / Sterilizer
Brand : SanShen
SKU : NB042591
Service :The delivery and service By NBCLab.Com
Vertical pulsating vacuum pressure steam Autoclave YMMD105L, using saturated steam to sterilize items through high temperature and high voltage, suitable for environmental protection, university scientific research, food chemical and other units to sterilize. The product is made of SUS304 stainless steel, with a volume of 105L, a design pressure of 0.38MPa, and a sterilizing Temperature range of 105~ 136 ℃.
1. SUS304 stainless steel material, Pressure Vessel wall thickness 2.5mm, large diameter vertical structure, radial self-expanding silicone sealing ring. 2. Dial rod 12-post latch synchronous telescopic primary switch structure, automatic vertical upward bounce when opening the lid, and the upper cover has heat insulation and anti-scalding protection. 3. Using electronic, mechanical, pressure, temperature chill down multiple safety chain protection devices, closed cover inspection system, the door is not closed properly equipment can not start, down to the set safe temperature and pressure will be unlocked, and there are open and close operation prompt tone. 4. Full-color 7-inch LCD screen on top, Chinese and English can be selected, touch operation selects sterilizing program and parameters, dynamic digital display pressure, temperature, time and alarm information, dynamic Linear dispersion display the whole process of operation. 5. Adopt three-level independent passwords and fingerprint recognition to control entry operations. 6. Built-in independent water tank and electric evaporator for easy sterilization room cleaning, water shortage alarm automatically cuts off the heating power supply. 7. Built-in steam condensation system, steam domestic circulation, pipeline closure without exhaust gas and wastewater discharge, to meet the needs of biosafety sterilization. 8. Equipped with High Accuracy Gas filtrating device, effectively filter out particles larger than 0.22um in diameter. 9. There is a wastewater sampling port, which is convenient for timely treatment of wastewater as required. 10. The sterilizing chamber has an external heating and insulation device, and the computer program can automatically adjust and control the heating temperature and time. 11. Equipped with Vacuum Level can reach oil-free vacuum pump below -0.09MPa, with pulsating vacuum and heating film double drying function. 12. Adopt low center of gravity, high load adjustable casters, and can be turned and shifted 360 °. 13. Microcomputer automatic control, preset equipment, parcel, solution, rubber, medical waste and foster base six one-button selection of fixed sterilizing program and preheating, insulation, dissolve three auxiliary programs, preset program parameters can be modified according to demand, and custom programs can meet a variety of sterilizing needs. 14. There are two programs, DB test and vacuum test, used to test the equipment's vacuum leakage rate, exhaust capacity, and steam penetration rate. 15. The appointment timing start and warm-up function can automatically run according to the appointment setting time, and the appointment time is set from 0 to 9999min. 16. For non-liquid programs, preheating, pulsation, heating, sterilizing, exhaust, drying process is fully automatic control, for liquid programs, preheating, heating, sterilizing, exhaust process is fully automatic control. 17. Standard printer, can print sterilized temperature, time, pressure, FO value and other sterilized data in real time. Another USB interface can copy the sterilized data automatically recorded by the system to save the U disk. 18. Equipped with Pt100 temperature sensor, TT/PT test interface for multi-point temperature and pressure verification. 19. It has the function of viewing the current time, sterilizing times, failure time and code, and has the functions of plateau pressure, inner chamber pressure and inner chamber temperature compensation. 20. Pulsating cold air automatic discharge, sterilizing end steam automatic full row, micro row, no row or manual discharge can be selected. 21. Double fan cooling chilling down system, return valve to prevent negative pressure function. 22. Background safety test program, automatic fault detection system, over-temperature, overvoltage, leakage, overcurrent, short circuit, low water level and all kinds of fault beep sound and light alarm, LCD screen display alarm code and alarm information, sterilize program automatically stop. 23. Power-off memory storage function, sterilize the end of sound and light prompts and text display "can open the door", with a quick maintenance window.
The equipment uses saturated steam to sterilize items in a high temperature and high voltage environment. Fully automatic control by microcomputer realizes processes including preheating, pulsation (for non-liquids), heating up, sterilizing, venting, drying (for non-liquids). Its built-in pulsation vacuum system can effectively remove cold air, ensure steam penetration, and realize domestic circulation of steam through the built-in steam condensation system, without exhaust gas and wastewater discharge.
Environmental protection, university scientific research, food and chemical industry
1. Enter the Operating system through three-level independent password or fingerprint recognition. 2. Select the preset sterilizing program (such as instrument, parcel, solution, rubber, medical waste, foster base) or custom program on the 7-inch Touchscreen, and modify the parameters according to needs. 3. Confirm that the door is closed (the closed cover inspection system ensures that the door is not closed properly and the device cannot be started). 4. The equipment runs automatically, completing the process of preheating, pulsation (if applicable), heating up, sterilizing, exhaust, drying (if applicable), etc. 5. After sterilizing, the device emits a sound and light prompt and displays "Open the door". Unlock the door after lowering to a safe temperature and pressure. 6. The sterilized data can be printed in real time through the standard printer, or the data can be copied to the U disk through the USB interface for storage.
Before the equipment runs, make sure that the door is fully closed, otherwise it cannot be started. • When the equipment is short of water, it will alarm and automatically cut off the heating power supply, which needs to be dealt with in time. • After sterilizing, wait for the device to drop to the set safe temperature and pressure before unlocking the door. • The equipment is equipped with a wastewater sampling port, and the wastewater needs to be treated in a timely manner as required. • The equipment has multiple Safety protection, in case of overtemperature, overvoltage, leakage and other faults, the program will automatically stop and sound and light alarm, need to be processed according to the alarm code and information displayed on the LCD screen. • For non-liquid programs, you can choose the steam discharge method after sterilization (full row, micro row, no row or manual). • The device has a power-off memory function, but you need to pay attention to check the program status when restarting after an unplanned power failure. Run the DB test and vacuum test program before use to verify the vacuum leakage rate and vapor penetration rate of the equipment. • The reservation function setting time range is 0~ 9999 minutes. Equipment is equipped with adjustable casters, please pay attention to smooth movement.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.