Made of SUS304 stainless steel, Pressure Vessel wall thickness 2.5mm. Volume 125L, Power 7kW. Built-in steam condensation system to achieve no exhaust wastewater discharge, and equipped with Vacuum Level -0.09MPa oil-free vacuum pump and pulsating vacuum drying function.
Category : Autoclave / Sterilizer
Brand : SanShen
SKU : NB042592
Service :The delivery and service By NBCLab.Com
Vertical pulsating vacuum pressure steam Autoclave YMMD125L uses saturated steam to sterilize the required items at high temperature and high voltage, which is widely used in environmental protection, university scientific research, food chemical and other units for sterilization.
1. SUS304 stainless steel material, Pressure Vessel wall thickness 2.5mm, large diameter vertical structure, radial self-expanding silicone sealing ring. 2. Dial rod 12-post latch synchronous telescopic primary switch structure, automatic vertical upward bounce when opening the lid, and the upper cover has heat insulation and anti-scalding protection. 3. Using electronic, mechanical, pressure, temperature chill down multiple safety chain protection devices, closed cover inspection system, the door is not closed properly equipment can not start, down to the set safe temperature and pressure will be unlocked, and there are open and close operation prompt tone. 4. The upper full-color 7-inch LCD screen can be used in Chinese and English, and the touch operation selects the sterilizing program and parameters. 5. Dynamic digital display pressure, temperature, time and alarm information, dynamic Linear dispersion display the whole process of operation, graphic display automatic sterilizing process. 6. Adopt three-level independent passwords and fingerprint recognition to control entry operations. 7. Built-in independent water tank and electric evaporator for easy sterilization room cleaning, water shortage alarm automatically cuts off the heating power supply. 8. Built-in steam condensation system, steam domestic circulation, pipeline closure without exhaust gas and wastewater discharge. 9. Equipped with High Accuracy Gas filtrating device, effectively filter out particles larger than 0.22um in diameter. 10. There is a wastewater sampling port, which is convenient for timely treatment of wastewater as required. 11. The sterilizing chamber has an external heating and insulation device, and the computer program can automatically adjust and control the heating temperature and time. 12. Equipped with Vacuum Level can reach oil-free vacuum pump below -0.09MPa, with pulsating vacuum and heating film double drying function. 13. Adopt low center of gravity, high load adjustable casters, and can be turned and shifted 360 °. 14. Microcomputer automatic control, preset equipment, parcel, solution, rubber, medical waste and foster base six one-button selection of fixed sterilizing program and preheating, insulation, dissolve three auxiliary programs, preset program parameters can be modified according to demand, and custom programs can meet a variety of sterilizing needs. 15. There are two programs, DB test and vacuum test, used to test the equipment's vacuum leakage rate, exhaust capacity, and steam penetration rate. 16. The appointment timing start and warm-up function can automatically run according to the appointment setting time. 17. For non-liquid programs, preheating, pulsation, heating, sterilizing, exhaust, drying process is fully automatic control, for liquid programs, preheating, heating, sterilizing, exhaust process is fully automatic control. 18. Standard printer, can print sterilized temperature, time, pressure, FO value and other sterilized data in real time. Another USB interface can copy the sterilized data automatically recorded by the system to save the U disk. 19. Equipped with Pt100 temperature sensor, TT/PT test interface for multi-point temperature and pressure verification. 20. It has the functions of viewing the current time, the number of deaths, the time of failure and the code, and has the functions of plateau pressure, inner chamber pressure and inner chamber temperature compensation. 21. The pulsating cold air is automatically discharged, and the steam at the end of sterilization is automatically discharged in full, micro, no or manual. 22. Double fan cooling chilling down system, return valve to prevent negative pressure function. 23. Background safety test program, fault automatic detection system, over temperature, overvoltage, leakage, overcurrent, short circuit, low water level and various fault beep sound and light alarm, LCD screen display alarm code and alarm information, sterilize program automatically stop. 24. Power-off memory storage function, sterilize the end of sound and light prompts and text display "can open the door", with a quick maintenance window.
The Autoclave uses saturated steam to sterilize items in a high temperature and high voltage environment. Its working process is fully automatically controlled by a microcomputer, including preheating, pulsating vacuum (for non-liquid items to discharge cold air), heating, sterilizing, venting, drying (non-liquid) and other stages to achieve effective killing of microorganisms.
Environmental protection, university scientific research, food and chemical industry
1. Enter the Operating system through three-level independent password or fingerprint recognition. 2. Select the preset sterilizing program (such as instrument, parcel, solution, rubber, medical waste, foster base) or custom program on the 7-inch Touchscreen, and modify the parameters. 3. Place the items to be sterilized and make sure the door is closed (the closed inspection system will verify). 4. Start the program, the equipment will automatically complete the whole process of preheating, pulsation (if applicable), heating up, sterilizing, exhaust, drying (if applicable) and so on. 5. After sterilizing, the device emits a sound and light prompt and displays "Open the door", and unlocks the door at a safe temperature and pressure. 6. The sterilized data can be printed in real time through the standard printer, or the recorded data can be copied to the U disk through the USB interface for storage.
• The device cannot be started if the door is not closed properly, please make sure the door is closed correctly. • The device has multiple safety chain protection, please unlock the door at the set safe temperature and pressure. • Pay attention to the water shortage alarm, the heating power will be automatically cut off when there is a water shortage. • The steam discharge method after sterilization (full row, micro row, no row or manual) can be selected according to needs. • The equipment has a wastewater sampling port, please treat the wastewater in time as required. • When encountering faults such as overtemperature, overvoltage, leakage, etc., the equipment will sound and light alarm and automatically stop the program. Please deal with it according to the alarm code and information displayed on the LCD screen. • The device has a power-off memory function, but please check the program status when restarting after unplanned power failure. • Familiarize yourself with DB testing and vacuum testing procedures before use to regularly test equipment performance. • Do not operate beyond the range of design pressure 0.38MPa (temperature 150 ° C) and operating pressure ≤ 0.23MPa. When moving the device, you can use its adjustable casters, but pay attention to its weight (Net weight 170kg).
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.