Overview
Tianma FA2105C 1/100,000 Electronic Balance adopts High Stability Electromagnetic Force Sensor technology, with novel Appearance, large Interior volume, stable performance and complete functions. The product has dual range weighing function, the highest accuracy is 0.01mg, suitable for High Accuracy weighing needs.
Features
1. High accuracy: High Accuracy Electromagnetic Force equilibrating Sensor, Precision measurement results, fast response speed, less faults
2. Optimized micro-loading weighing function: Digital processing technology is used to greatly improve the Response speed of micro-loading while maintaining the stability of Balance reading
3. Built-in weighing function: basic weighing function, piece weighing function, percentage weighing function
4. Balance: automatic built-in weight calibrating
5. Dual range weighing
6. Maximum accuracy up to 0.01mg
7. Transparent Glass Windshield
8. LCD LCD display
9. Unique split design
10. Built-in RS232 communication interface
11. Fault detection function
12. Overload protection, percentage display
13. Unit conversion function
Principle
The Electronic Balance uses electromagnetic force equilibrating Sensor technology to accurately measure mass by equilibrating electromagnetic force with sample gravity. When the sample is placed on the pan, the Sensor generates the corresponding electromagnetic force to equilibrate gravity, and determines the mass of the sample by measuring the magnitude of the electromagnetic force.
Applications
Laboratories, scientific research institutions, pharmaceuticals, chemicals, food, education, Quality control
Standards
E2 test weight standard
Steps
1. Place Balance on a Stable Workbench
2. Connect the power supply and preheat for 30-60 minutes
3. After waiting for stability, perform automatic built-in weight calibrating
4. Select the desired weighing mode (basic weighing, piece weighing, or percentage weighing).
5. Place the sample on the pan for weighing
6. Read measurement results through LCD LCD display
7. Data can be transmitted by connecting external devices through the RS232 interface
Notice
• The working environment temperature should be kept within the range of + 10~ + 30 ° C
• The relative humidity should be controlled between 20 and 85% to avoid condensation
• Preheat for 30-60 minutes before use to ensure Measurement accuracy
• Avoid overloading to avoid damaging the Sensor
Periodically calibrated to ensure measurement accuracy
• Keep the pan clean to avoid contamination affecting the measurement results
• Power supply voltage must meet AC230V, 50-60HZ requirements