Overview
TAISITE WGL-45D electric air blowing dryer is a vertical drying equipment with PID intelligent temperature control, which has the characteristics of uniform temperature, convenient operation and safety and reliability. Its studio volume is 45L, Temperature range RT + 10~ 300 ℃, suitable for drying all kinds of samples.
Features
1. Adopt PID intelligent temperature control to quickly reach the set value and operate stably
2. Convenient operation, support fixed-value operation, regular operation, automatic stop, appointment start
3. Special function keys to achieve temperature setting, auxiliary menu provides over-rise alarm, deviation correction, menu lock function
4. Vertical double air duct air jacket, turbine centrifugal forced air supply, uniform temperature distribution
5. Speed control fan design, suitable for lightweight, fine, powdery samples
6. Forced fan cooling intake structure to ensure long-term operation of the fan at < 50 ° C
7. Insulation door technology, the outer door temperature is low and does not deform when used at high temperature
8. Pull-out tray Shelf design, easy and fast to take samples
9. Optional self-developed digital display overlift preventer to improve temperature control accuracy and safety
10. Owns a number of patented technologies (patent numbers: ZL201630486063.2, ZL201320059701.3, ZL201921000740.X, ZL201920940767.0, ZL201921001075.6)
Principle
The drying oven generates heat through a stainless steel heating tube, adopts a double air duct forced convection method, and is forced by a turbine centrifugal fan to circulate hot air in the studio to ensure uniform temperature distribution. The PID intelligent temperature control system precisely adjusts the temperature and realizes stable operation.
Applications
Laboratories, scientific research institutions, industrial production, mass testing, material processing
Standards
The product does not mention specific compliance standards
Steps
1. Turn on the power supply and set the desired temperature
2. Select the operation mode (fixed-value operation, regular operation, etc.)
3. Set the timing time (0~ 9999 minutes)
4. Start the device and wait for the temperature to reach the set value
5. Place the sample on the pull-out tray
6. The device automatically stops after the operation is completed
Notice
• Power supply voltage meets requirements before use (220V/5.5A)
• Do not overload, Load per shelf is 15kg
• Avoid direct contact with the outer door during high temperature operation to prevent burns
• Regularly check the operating status of the fan to ensure normal heat dissipation
• When an overlift preventer is optional, install and use it according to the instructions
• Disconnect the power supply when the equipment is out of service, keep it clean and drying