Overview
TAISITE WGL-230L electric air blowing dryer is a vertical drying equipment using PID intelligent temperature control technology, which has the characteristics of uniform temperature, convenient operation and safety and reliability. Its studio volume is 230L, Temperature range RT + 10~ 300 ℃, suitable for drying all kinds of samples.
Features
1. Adopt PID intelligent temperature control to quickly reach the set value and operate stably
2. Convenient operation functions, including fixed-value operation, regular operation, automatic stop and scheduled start
3. Dedicated function keys to achieve temperature setting, auxiliary menu supports over-rise alarm, deviation correction and menu lock
4. Vertical double air duct air sleeve design, turbine centrifugal forced air supply to ensure uniform temperature distribution
5. Speed control fan design, suitable for lightweight, fine, powdery samples
6. Forced fan cooling intake structure to ensure long-term operation of the fan at < 50 ° C
7. Insulation door technology, the outer door temperature is low and does not deform when used at high temperature
8. Pull-out tray Shelf design, easy and fast to take samples
9. Self-developed digital display overlift preventer, accurate and stable temperature control, safe and reliable
10. L-type LCD multi-data full-screen operation display, supports power failure memory and power failure compensation functions
Principle
The equipment generates heat from the nickel-chromium alloy heating wire through the rotary air supply mode of the bottom air duct, and the turbine centrifugal fan forcibly circulates hot air to form a uniform temperature field. The PID intelligent temperature control system monitors and adjusts the temperature in real time to ensure that the studio temperature quickly reaches the set value and remains stable.
Applications
Laboratories, scientific research institutions, industrial production, mass testing, material processing, pharmaceutical production, Food processing
Standards
Patent number: ZL201630486063.2, ZL201320059701.3, ZL201921000740.X, ZL201920940767.0, ZL201921001075.6
Steps
1. Turn on the power supply and set the required temperature parameters
2. Select the operation mode: fixed-value operation or regular operation
3. Start the device and wait for the temperature to reach the set value
4. Put in the sample for drying
5. After the processing is completed, the device will automatically stop or manually shut down
Notice
• Power supply voltage meets equipment requirements (AC220V/13.6A) before use
• Do not touch high-temperature parts while the device is running
• Regularly check the operating status of the fan
• Avoid overload. Load per shelf 15kg
• Keep equipment well ventilated
• Disconnect the power supply when not in use for a long time