Overview
TAISITE WGL-45T electric air blowing dryer is a vertical drying equipment using PID intelligent temperature control technology, which has the characteristics of uniform temperature, convenient operation and safety and reliability. Its studio volume is 45L, Temperature range RT + 10~ 300 ℃, suitable for drying all kinds of samples.
Features
1. Adopt PID intelligent temperature control to quickly reach the set value and operate stably
2. Convenient operation, support fixed-value operation, regular operation, automatic stop and scheduled start
3. Special function keys to achieve temperature setting, auxiliary menu provides over-rise alarm, deviation correction and menu lock function
4. Vertical double air duct air sleeve design, turbine centrifugal forced air supply to ensure uniform temperature
5. Speed adjustable fans are suitable for lightweight, fine, and powdery samples
6. Forced fan cooling intake structure to ensure long-term operation of the fan at < 50 ° C
7. Insulation door technology, the outer door temperature is low and does not deform when used at high temperature
8. Pull-out tray Shelf design, easy and fast to take samples
9. Self-developed digital display overlift preventer, accurate and stable temperature control, safe and reliable
10. With over-lift alarm, menu lock and over-lift prevention functions
Principle
The equipment generates heat through a stainless steel heating tube, and adopts a double air duct forced convection method. The turbo centrifugal fan forces the air to circulate the hot air inside the studio. The PID intelligent temperature control system monitors and adjusts the temperature in real time to ensure a stable and uniform distribution of temperature.
Applications
Laboratories, scientific research institutions, industrial production, mass testing, material handling, drug drying
Standards
Patent number: ZL201630486063.2, ZL201320059701.3, ZL201921000740.X, ZL201920940767.0, ZL201921001075.6
Steps
1. Turn on the power supply and turn on the device switch
2. Set the required temperature and time parameters through the touch screen
3. Select the operation mode: fixed-value operation or regular operation
4. Set the reservation start function as needed
5. Place the sample on the pull-out tray Shelf
6. Start the device and monitor the running status
7. Automatically stop after the run and take out the sample
Notice
• Power supply voltage meets AC220V requirements before use
• Do not overload, Load per shelf is 15kg
• Avoid direct contact with the outer door during high temperature operation
• Regularly check the operating status of the fan
• Keep the exhaust port open
• Do not change settings at will while the device is running
• Disconnect the power supply when not in use for a long time