Transverse wind circulation structure is adopted, which is conducive to air mixing and fast drying rate. Forced fan cooling intake structure makes the maximum operating temperature of the fan lower than 50 ° C to ensure longevity. With program temperature control function, 50 experimental programs can be stored.
Category : Drying Oven
Brand : TaiSiTe
SKU : NB043093
Service :The delivery and service By NBCLab.Com
TAISITE 101-3DB (with program mode) electric air blowing dryer is a laboratory device with a lateral wind circulation structure and a 225L large-capacity studio. It uses a digital tube dual-column PID Control mode for precise temperature control. Temperature range is from room temperature plus 10 ° C to 250 ° C, Temperature Fluctuation is +/- 1.0 ° C, and Uniformity is +/- 2.5%. The device supports set-value operation, timing operation and automatic stop, and comes standard with program mode to store up to 50 experimental programs to meet complex experimental needs.
1. The use of transverse wind circulation structure is conducive to air mixing, high space utilization, and fast drying rate. 2. Convenient operation, support fixed-value operation, regular operation, and automatic stop. 3. Dedicated function keys to achieve temperature setting. 4. Auxiliary menu to achieve over-rise alarm, deviation correction, menu lock. 5. Forced fan cooling intake structure, the fan maximum Operating temperature < 50 ℃, to ensure long life operation. 6. Equipped with safety functions such as over-rise alarm and menu locking. 7. Standard program mode, single-stage temperature control and program temperature control can be converted to each other, 50 experimental programs can be stored, each program can be set to 50 steps, each step can be set to 0-6000 minutes adjustable. 8. With deviation correction, menu button lock, power outage compensation, power outage memory and other additional functions.
The electric air blowing dryer generates heat through a stainless steel heating tube, and the hot air is evenly blown into the studio by the side air duct forced convection system (lateral wind circulation) to achieve fast and uniform heating and drying. The equipment adopts a PID intelligent temperature controller, which monitors the temperature in the box in real time through the Pt100 temperature sensor, compares and calculates with the set value, and automatically adjusts the Heating power to maintain an accurate and stable temperature environment.
Laboratory sample drying, material heat treatment, electronic component aging, chemical product drying, biological product dehydration, agricultural research, pharmaceutical research and development, food testing
The data did not mention specific compliance criteria
1. Turn on the power supply (AC220V). 2. Set the desired temperature and time by tapping the four buttons (Timer Range 0~ 9999 minutes, with timed wait). 3. Select the operation mode: set-value operation, regular operation or call the preset program to run. 4. Start the equipment, the equipment starts heating and running. 5. After the operation is completed, the device will automatically stop and issue a prompt (if the timing is set or the program ends). 6. After the temperature in the box chills down, take out the sample and turn off the power.
* The equipment should be placed on a well-ventilated and stable countertop. * Do not place flammable, explosive, volatile and corrosion items in the box. * The maximum load of a single shelf is 15kg, do not overload. * When the equipment is running, do not frequently open and close the box door, so as not to affect the temperature Stability. The exhaust port at the top of the equipment should be kept unobstructed. * Operating temperature should not exceed the rated upper limit of 250 ° C. Equipment with over-rise alarm function, in case of abnormal high temperature alarm, please check immediately. * Be sure to cut off the power before cleaning, until the box is completely chilled down. Non-professional personnel should not disassemble or modify the equipment. * Pay attention to the power requirements of the equipment (AC220V/18.2A 50/60Hz) to ensure that the power supply matches.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.