Please contact customer service
Adopt LCD dual-row PID temperature control, Temperature Fluctuation only +/- 1.0 ℃, resolution 0.1 ℃. Standard program mode, can store 50 programs, 50 steps per program. Double-decked thermal insulation door and natural convection design ensure Temperature uniformity and operation safety.
Category : Drying Oven
Brand : TaiSiTe
SKU : NB043109
Service :The delivery and service By NBCLab.Com
The TAISITE WHLL-45BE electrothermal static drying oven is a programmed laboratory device with High Accuracy, easy operation and safety. With an internal volume of 45L and LCD dual-column PID control, it has a wide Temperature range and is suitable for a variety of experimental scenarios requiring thermostatic drying.
1. High Accuracy Temperature Control: Temperature resolution 0.1 ℃, Temperature Fluctuation +/- 1.0 ℃, Temperature distribution accuracy +/- 3.5%. 2. Convenient operation: touch four buttons to set, special function keys to achieve temperature setting, auxiliary menu to achieve over-rise alarm, deviation correction, menu lock and other functions. 3. Powerful program mode: standard program mode, single-stage temperature control and program temperature control can be converted to each other, 50 experimental programs can be stored, each program can be set to 50 steps, and the time of each step can be adjusted from 0 to 6000 minutes. 4. Diverse operation functions: support fixed-value operation, regular operation (0-9999 minutes, with timing waiting function) and automatic stop. 5. Safe and reliable: equipped with over-lift alarm and over-lift preventer, with power outage compensation and power outage memory functions. 6. Excellent structural design: double-decked heat insulation door design, vertical double air duct air sleeve and turbine centrifugal forced air supply to ensure uniform temperature, adjustable multi-layer Shelf spacing, easy to place items of different heights, and with exhaust holes.
The drying oven generates heat through a nickel-chromium alloy heating wire, and uses a natural convection method (combined with a turbine centrifugal forced air supply system) to circulate the air in the box to ensure uniform temperature in the studio. The temperature sensor (pt100) monitors the temperature in the box in real time and feeds the signal back to the LCD dual-column PID controller. The controller precisely calculates the deviation of the set temperature and the measured temperature, and adjusts the output power of the heating device to achieve thermostatic control. The program mode allows the user to preset complex temperature-time Linear dispersion, and the device is automatically executed according to the steps.
Laboratory sample drying, material heat treatment, component aging, biological product drying, chemical industry thermostatic experiment
Not mentioned
1. Connect the AC220V power supply. 2. Set the target temperature, time and other parameters through the touch button of the control panel, or select the preset program. 3. If you need the program to run, enter the program mode setting or call the stored program. 4. Place the sample on the shelf and close the double-decked door. 5. Start the equipment and start the heating operation. 6. The equipment is set according to the setting value or program temperature control, and automatically stops and alarms after reaching the set time. 7. After the experiment, remove the sample and turn off the power.
* Equipment should be placed in a smooth, well-ventilated environment. * Load per shelf no more than 15kg when placing items, and should not block the air duct. * Temperature range is room temperature + 10 ℃ to 300 ℃, do not use beyond the range. * Do not open the door frequently during operation, so as not to affect Temperature uniformity and equipment life. * Please disconnect the power supply when cleaning, wipe with a soft cloth, and avoid the use of corrosion cleaners. Regularly check whether the exhaust hole is unobstructed. In the event of a malfunction alarm (such as an over-lift alarm), please identify the cause and eliminate it before using it. Non-professional personnel should not disassemble or modify the equipment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.