Please contact customer service
Vertical double air duct centrifugal forced air supply, Temperature Uniformity of +/- 2.5%, equipped with speed regulating fan can handle light and small samples, forced cooling structure to ensure the longevity of the fan.
Category : Drying Oven
Brand : TaiSiTe
SKU : NB043116
Service :The delivery and service By NBCLab.Com
The TAISITE GX125B (with program mode) Hot Air Sterilizer is a vertical dual air duct forced convection sterilizer that uses turbine centrifugal forced air supply technology to ensure uniform temperature in the furnace. The equipment has a Temperature range of RT + 10 to 300 ° C, Temperature Fluctuation is +/- 1 ° C, and resolution is up to 0.1 ° C. It is suitable for occasions where accurate and reliable sterilization is required. The product has fixed-value operation, scheduled operation and automatic stop functions, and comes standard with program mode. It supports single-stage and program temperature control conversion, and can store up to 50 experimental procedures for easy operation.
1.Quickly, safely and reliably sterilize. 2. Convenient operation, support fixed-value operation, regular operation, and automatic stop. 3. Special function keys to achieve temperature setting, auxiliary menu provides over-rise alarm, deviation correction, menu lock function. 4. Vertical double air duct air sleeve design, combined with turbine centrifugal forced air supply, more uniform temperature distribution. 5. Speed control fan design, suitable for light, small, powdery samples. 6. Forced fan cooling intake structure to ensure that the maximum Operating temperature of the fan is lower than 50 ° C to achieve longevity. 7. LCD multi-data control panel (BE model with power outage memory and compensation functions). 8. Equipped with multi-functional safety locks and insulated safety doors to enhance safety and comfort. 9. Linear dispersion can display the temperature rise in the furnace, reflecting professional and accurate temperature control.
The hot air sterilization box generates heat through stainless steel heating pipes, and adopts a vertical double air duct air sleeve structure. It is forced by a turbo centrifugal fan to form a forced convection, so that the hot air is in the studio (liner is stainless steel plate) domestic circulation, ensuring uniform temperature distribution. The equipment monitors the temperature in real time through the PT100 temperature sensor, and is precisely adjusted by the digital tube dual-column PID Control system to achieve the set temperature Linear dispersion. Program mode supports multi-stage temperature control, which can store and run complex temperature programs.
Laboratory sterilizing, medical apparatus disinfection, sample drying, material heat treatment, Powder Sample Handling
Not mentioned
1. Connect the AC 220V power supply. 2. Set the target temperature and time by tapping the four buttons (Timer Range 0-9999 minutes, with timing and waiting function). 3. Select the operation mode: set-value operation, regular operation or call the preset program (standard program mode, 50 programs can be stored, and each program can take up to 50 steps). 4. Start the equipment, the fan starts forced convection air supply, heating pipe work. 5. The equipment will run automatically according to the settings and stop automatically when the conditions are met. 6. Real-time temperature and Linear dispersion can be observed through the control panel during operation.
Cold rolled steel plate painting, thermal insulation safety door can reduce the surrounding temperature, but still need to pay attention to avoid touching high temperature parts. * Before use, please confirm that the Power supply voltage is AC220V/50-60Hz and ensure good grounding. * Load per shelf is 15kg, do not overload. The equipment is equipped with an over-lift alarm function. If the alarm is triggered, please check the set parameters in time. * You can use the auxiliary menu for deviation correction or lock the menu key to prevent misoperation. * The top of the equipment is equipped with a φ 28mm exhaust port, please ensure that the Operating Environment is well ventilated. * Net weight 60kg (gross weight 66kg), handle with care.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.