Please contact customer service
Adopt vertical double air duct air jacket and turbine centrifugal forced air supply, Temperature Uniformity up to +/- 2.5%. Equipped with a speed regulating fan, it can handle light, fine and powdery samples, and has an overlift preventer and program mode to support multi-stage temperature control.
Category : Drying Oven
Brand : TaiSiTe
SKU : NB043117
Service :The delivery and service By NBCLab.Com
TAISITE GX30BE (with program mode) Hot Air Sterilizer is a device using vertical double air duct air jacket and turbine centrifugal forced air supply technology, designed to provide fast, safe and reliable sterilizing effect. The device has LCD multi-data full-screen operation display, supports fixed-value operation, timing operation, automatic stop and program temperature control and other operation modes, and is equipped with over-rise preventer, power failure memory and compensation and other safety and auxiliary features, suitable for sterilizing applications with high requirements for Temperature uniformity.
1. Quick, safe and reliable sterilizing effect. 2. Convenient operation, support fixed-value operation, regular operation and automatic stop. 3. Special function keys to achieve temperature setting, auxiliary menu supports over-rise alarm, deviation correction, menu lock. 4. Adopt vertical double air duct air jacket, turbine centrifugal forced air supply to ensure more uniform temperature. 5. Speed control fan design, suitable for light, small, powdery samples. 6. Forced fan cooling intake structure, so that the maximum Operating temperature of the fan is lower than 50 ℃, to ensure long-term stable operation. 7. Functional LCD multi-data full-screen operation display, with power outage memory and power outage compensation functions (BE model). 8. Equipped with an overlift preventer to enhance safety. 9. Detailed design advantages include: LCD multi-data control panel, multi-functional safety lock, Linear dispersion diagram display of temperature rise in the furnace, thermal insulation safety door (the periphery of the instrument is not hot during work).
The hot air sterilization box generates heat through stainless steel heating pipes, and uses a vertical double air duct air sleeve structure, which is forced convection by a turbo centrifugal fan to make the hot air in the studio (liner is stainless steel) domestic circulation, so as to achieve uniform and fast heating and disinfection. The equipment adopts LCD dual-column PID temperature Control mode, which accurately monitors the temperature through the pt100 Sensor, and can perform multi-stage temperature control through the program mode to ensure accurate and stable temperature.
Sterilizing, Sample Handling, Powder heating, Small parts drying
Not mentioned
1. Connect the AC 220V power supply. 2. Set the target temperature and time by tapping the four buttons (Timer Range 0~ 9999 minutes, with timing waiting function). 3. Select the operation mode: fixed-value operation, regular operation, or program temperature control mode (50 programs can be stored, with a maximum of 50 steps per program). 4. Start the equipment, the fan forced convection, began heating sterilized. 5. After the operation, the device will automatically stop. 6. Real-time temperature, set temperature and running status can be viewed through the LCD screen.
• Power supply voltage is AC 220V 50/60Hz. • When the equipment is working, do not touch the heating part. Although the thermal insulation safety door is designed to make the surrounding area not hot, it is still necessary to pay attention to safety. • Load per shelf is 15kg, please do not overload. • Please confirm that safety devices such as overlift preventer are functioning normally before use. • The device has a menu lock function to prevent misoperation, please manage it properly. • The top of the equipment is equipped with a φ 28mm exhaust port, please ensure that the Operating Environment is well ventilated. When moving or cleaning equipment, pay attention to its Net weight (32kg) and Dimensions. • If you need to add configuration (such as RS485 interface, printer, etc.), please refer to the model corresponding to the selection.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.