Adopt microcomputer PID intelligent temperature control, precise temperature control. Ultimate vacuum degree up to 50Pa, and has 5-stage 5-cycle Vacuum Level programming control function. Vertical integrated structure, standard hidden vacuum pump, equipped with large observation window and mobile casters.
Category : Drying Oven
Brand : TaiSiTe
SKU : NB043129
Service :The delivery and service By NBCLab.Com
TAISITE TDZZ-L2215L (with program mode) vertical electric heating Vacuum oven is a drying equipment for research applications in electronics, aerospace, military weapons, automobiles and ships, Petrochemicals, agriculture and forestry environmental protection, commodity inspection, disease control, biochemistry, environment protection, etc. It is especially suitable for rapid drying of substances such as heat sensitivity, easy analysis, easy oxidation, and complex compositions in scientific research, universities, and enterprises, and can also be used for accelerated drying of powders and Miscellaneous substances.
1. Microcomputer integrated intelligent temperature control system, PID logic operation function, accurate and reliable temperature control. 2. The color LCD screen displays the operating temperature and the set temperature. 3. With automatic saving of emergency parameters, call recovery function, and Sensor self-diagnosis, over-temperature and fault alarm function. 4. Adopt one-time forming silicone sealing ring, high temperature resistance, Aging Resistance, better sealing effect. 5. Large observation window, Transmittance 96% acrylic plate is used on the outer layer, and high-strength tempered Glass is used on the inner layer. 6. Vertical integrated structure, standard concealed vacuum pump. 7. Vacuum Level automatic control and maintenance, digital Vacuum Level, the minimum vacuum value is 10Pa, Ultimate vacuum degree can reach 50Pa. Vacuum Level can be programmed in 5 stages and 5 cycles. 8. High Accuracy Resistance Vacuum Sensor, Vacuum Level real-time measurement. 9. Vacuum connection using KF25 fast interface, corrugated stainless steel vacuum connection tube, rapid, pressure, safe sealing. 10. Equipped with mobile casters for quick transfer.
The device performs PID logic operation through the microcomputer integrated intelligent temperature control system, and precisely controls the heating device to heat the studio. At the same time, through the built-in vacuum pump and Vacuum Level automatic Control system, the pressure in the working room is reduced to the set Vacuum Level, and the vacuum environment is maintained by programming control during the drying process. This heating method in a low pressure (vacuum) environment can effectively reduce the boiling point of substances, accelerate the volatilization of water or solvents, and realize fast and low temperature drying, especially suitable for heat-sensitive and easy oxidation substances.
Electronics, aerospace, military weapons, automobiles and ships, Petrochemicals, agriculture and forestry environmental protection, commodity inspection, disease control, biochemistry, environment protection
1. Turn on the power supply and turn on the device. 2. Set the required operating temperature, Vacuum Level program (can be programmed in 5 stages and 5 cycles) and timing parameters through the color LCD screen. 3. Put the sample to be dried into the studio and close the box door to ensure sealing. 4. Start operation, the equipment will automatically carry out heating and vacuum control according to the set program. 5. The drying process can be observed through a large observation window. 6. After the program runs or reaches the set time, the equipment automatically stops, and the normal pressure is restored after chilling down, and the sample is taken out.
Equipment should be placed in a smooth, well-ventilated environment. • Load per shelf must not exceed 15kg when placing samples. • Make sure the door is closed tightly to ensure the vacuum sealing effect. • During the operation of the equipment, do not open the door frequently or perform unnecessary operations. • Pay attention to the operation status of the equipment. In case of over-temperature or fault alarm, it should be dealt with in time. The equipment is equipped with over-temperature alarm, overcurrent and overload protection, fast fuse, grounding protection and other safety devices, and its effectiveness needs to be checked regularly. • After use, the power should be turned off according to the procedures.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.