Overview
HUITAI GDT-225CH high and low temperature alternating climate chamber is a professional temperature and humidity testing equipment, providing a wide Temperature range of -60~ 150 ℃ and 20%~ 98% relative humidity control. The equipment uses advanced equilibrate Conditioning Control mode, equipped with 7 inch TFT color LCD display and multiple operating modes, suitable for various environment Reliability test.
Features
1. Adopt BTC equilibrate temperature control + DCC intelligent cooling capacity control + DEC intelligent electrical control
2.7-Inch TFT color LCD display with support for RMCS control software
3. Support fixed value mode and program mode, preset 100 groups of 100 steps 999 cycles
4. RAM with battery protection, maximum recording time 350 days
5. France Taikang fully enclosed Compressor, high efficiency slope evaporator
6. Multiple safety protection systems, including Compressor protection, humidification system protection and test chamber protection
7. Support RS-485 and Ethernet communication, compatible with a variety of operating systems
Principle
The equipment adopts BTHC equilibrate Conditioning Control mode, and realizes accurate temperature and humidity regulation through DCC intelligent cooling capacity control and DEC intelligent electrical control. It adopts cascade Compressor refrigeration system, equipped with high-efficiency slope evaporator and SWEP plate cold heat exchanger, and realizes stable environment simulation through precise Sensor and control system.
Applications
Temperature test, humidity cabinet test, high and low temperature alternating test, environment Reliability test, product mass test
Standards
GB/T5170.2-2008、GB/2423.1-2008、GB/2423.2-2008、GB/T5170.5-2008、GJB150.3、GJB150.4、GB2423.3-93、GB2423.4-93
Steps
1. Connect the power supply and check the device status
2. Set test parameters through a 7-inch TFT color LCD display
3. Select setting mode or program mode to run
4. Monitor the test process and data recording
5. Export data via USB or network after the test is completed
Notice
• The device needs to be powered by a 380V/32A power supply
• Check whether the water supply system is normal before operation
• Pay attention to Compressor overpressure protection and motor overheating protection
• Regularly check the status of drying Filter and solenoid valve
• Pay attention to the connection of the water cooling system when the device moves
• The test load shall not exceed the standard load capacity of 1kg aluminum sheet 200W heat generation
• Keep the observation window clean to ensure internal lighting effects