Please contact customer service
With a wide temperature range of -60 to 150 ° C and 20% to 98% humidity control, it adopts cascade Compressor refrigeration and intelligent cooling capacity control, supports program operation and remote communication, and ensures test stability and data recording.
Category : High Low Temperature Test Chamber
Brand : HuiTai
SKU : NB044261
Service :The delivery and service By NBCLab.Com
HUITAI GDT-800CH high and low temperature alternating climate box is a test equipment used to simulate high and low temperature and heat and humidity environment, with a studio volume of 800L. The equipment provides a variety of temperature range options (such as -60 ℃ to 150 ℃), and optional humidity control function (20%~ 98% R. H), suitable for product reliability testing. The equipment adopts advanced equilibrate Conditioning control mode, and is equipped with intelligent cooling capacity and electrical control system to achieve accurate and stable environment simulation.
1. Adopt a 7-inch TFT color LCD display, which can be connected to the host computer's RMCS control software for remote operation. 2. Support setting mode and program mode operation. The program mode can preset 100 groups of programs, each group of 100 steps, and support 999 cycles. 3. Adopt BTC/BTHC equilibrating temperature (humidity) control mode, combined with DCC intelligent cooling capacity control and DEC intelligent electrical control. 4. With powerful Linear dispersion recording function, built-in RAM with battery protection, the maximum recording time can reach 350 days (when the sampling period is 1 minute). 5. Provide RS-485 interface (MODBUS RTU protocol) and Ethernet interface (TCP/IP protocol) to support secondary development and remote connection of multiple devices. 6. The core of the refrigeration system adopts the French Taikang fully enclosed Compressor, and the high-efficiency slope evaporator and SWEP plate cold and heat exchanger are used. 7. With a complete safety protection system, covering Compressor, humidification system, test chamber and power supply and other aspects of fault alarm and protection functions. 8. The observation window is internally illuminated with LED and can be heated to prevent fogging. 9. Adopt nitrogen flushing welding, oxygen-free copper pipe, bending machine and other precision installation processes to ensure system reliability and life.
The equipment creates the required temperature and humidity environment in a closed working room through a mechanical compression refrigeration system (single stage or cascade) and a heating system, combined with humidification and dehumidification devices. The control system collects the environment parameters in the box in real time through the A-class PT100 armored Thermocouple (temperature) and dry wet-bulb temperature meter (humidity) method, and uses the equilibrate Conditioning control algorithm (BTC/BTHC) to coordinate the actions of the refrigeration, heating, humidification, dehumidification and other executive components, quickly and accurately achieve and maintain the set temperature and humidity conditions, and realize the environment simulation of fixed value or Linear dispersion changes according to the preset program.
Electronic product reliability testing, automotive parts environmental testing, material research, aerospace parts testing, military products environmental adaptability assessment, chemical product stability testing, biological product storage conditions simulation
GB/T5170.2-2008、GB/2423.1-2008、GB/2423.2-2008、GB/T5170.5-2008、GJB150.3、GJB150.4、GB2423.3-93、GB2423.4-93
Connect the device to a 380V power supply and ensure that the water supply is normal (if a humidity test is performed). 2. Set the temperature, humidity, time and other parameters required for the test through the 7-inch Touchscreen or connect to the host computer software, or select the preset program. 3. Put the sample to be tested into the studio and close the box door. 4. Start the equipment and run the test. 5. During the test, the data and Linear dispersion can be monitored in real time through the screen, software or data interface (USB, Ethernet, etc.). 6. After the test is completed, the equipment stops running according to the setting and the sample is taken out. 7. Historical data can be exported via USB interface, or remote data management can be performed via Ethernet.
The equipment should be installed in a well-ventilated place without direct sunlight and away from heat sources. • Power frequency is stable at 380V and has sufficient capacity (50A). Before conducting the humidity test, check the quality of the humidified water and the water supply system to avoid water shortage or abnormal water supply. When placing the sample, the air duct in the working room should not be blocked, and the total load (calorific value) should not exceed the standard load (200W). • When the equipment is running, do not open the box door frequently, so as not to affect the stability of temperature and humidity and the life of the equipment. • Regularly check whether the refrigeration system, filtrating device and safety protection function are normal. Equipment is equipped with multiple protections such as leakage, short circuit, and over-temperature, but operators still need to abide by electrical safety regulations. • If not used for a long time, the humidification water should be emptied, and the equipment should be cleaned and regularly powered on for maintenance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.