Overview
HUITAI GDT-1000AH high and low temperature alternating climate box is a professional temperature and humidity testing equipment, providing -20~ 150 ℃ Temperature range and 20%~ 98% relative humidity control. The equipment adopts 7-inch TFT color LCD display, supports setting mode and program mode operation, and has perfect protection function and data recording ability.
Features
1. Adopt BTC equilibrate Temperature Control mode + DCC intelligent cooling capacity control + DEC intelligent electrical control
2.7-Inch TFT color LCD display, supports RMCS control software connection
3. Support fixed value mode and program mode, preset 100 groups of 100 steps and 999 cycles
4. RAM data logging function with battery protection, the maximum recording time is 350 days
5. Provide RS-485 interface and Ethernet interface to support secondary development
6. France Taikang fully enclosed Compressor, high efficiency refrigeration system
7. Perfect safety protection system, including Compressor protection, humidification system protection and test chamber protection
Principle
The equipment adopts equilibrate Conditioning Control mode, which realizes accurate temperature and humidity regulation through intelligent cooling capacity control and intelligent electrical control. The temperature sensing adopts A-class PT100 armored Thermocouple, and the humidity control adopts wet-bulb temperature meter method. The refrigeration system adopts mechanical single-stage compression or cascade Compressor refrigeration mode, and is equipped with high-efficiency evaporator and SWEP plate cold and heat exchanger.
Applications
Electronic product testing, material research, automotive parts testing, aerospace, military product testing, scientific research experiments
Standards
GB/T5170.2-2008、GB/2423.1-2008、GB/2423.2-2008、GB/T5170.5-2008、GJB150.3、GJB150.4、GB2423.3-93、GB2423.4-93
Steps
1. Connect power 380V/50A
2. Set operating parameters through a 7-inch TFT color LCD display
3. Select setting mode or program mode to run
4. Monitor equipment operating status and data logging
5. Export data via USB or Ethernet interface
6. Turn off the device according to the procedures after completing the test
Notice
Equipment must be used under standard load conditions
• Pay attention to the phase sequence and phase loss protection of the power supply
• Regularly check the water supply status of the humidification system
• Ensure that the refrigeration system pressure is normal
• Pay attention to the use and maintenance of the observation window
• Regularly calibrate the Temperature and Humidity Sensor
• Keep equipment well ventilated
• Perform maintenance in strict accordance with the operation manual