$ 3488.00Ex works
Adopt equilibrating Conditioning Control system, Temperature range -60~ 150 ℃, humidity control 20~ 98% RH, with multi-stage intelligent output and energy saving function, special air circulation design to ensure uniform temperature, built-in a variety of protection systems to ensure safe operation.
Category : Temperature Humidity Chamber
Brand : AISRY
SKU : NB044741
Service :The delivery and service By NBCLab.Com
Programmable constant temperature and humidity testing machine NBC-150L-60 is mainly used to detect the performance of materials in various environments, test the heat resistance, cold resistance, dry resistance and moisture resistance performance of various materials. The equipment adopts equilibrate Conditioning Control System (BTHC), which transmits the actual data in the test chamber to the controller through the induction system. The controller controls the SSR multi-stage intelligent output, and the equilibrate temperature and humidity system output power to ensure that the temperature and humidity in the test chamber are fully stable. It has energy-saving functions and reduces the power used to ensure long-term accurate and stable operation of the instrument.
1. The product has beautiful appearance, reasonable structure, precise process, simple and convenient operation, stable and reliable performance. 2. The controller uses a large-scale color liquid crystal man-machine touch dialog LCD man-machine interface, which displays the operating status of the system in both Chinese and English, and supports RS232 computer interface remote control. 3. The refrigeration circulation system adopts the original imported Japanese "Sanyo" brand fully enclosed Compressor, the components come from Japan, France, the United States, Italy and other origins, and the refrigerant adopts the American environmentally friendly refrigerant. 4. Reserve a 50mm diameter test hole on the left side of the test chamber. 5, with fully automatic, high precision system loop, using P.I.D automatic calculation control, the whole area temperature High Accuracy, High Stability. 6. Specially designed air circulation circulation system and sensing system to ensure Temperature Uniformity and avoid dead ends. 7. Adopt enlarged observation window, 4 layers of whole empty tempered Glass, wide field of vision. 8. The instrument is equipped with a comprehensive protection system, including power overload protection, leakage protection, over-temperature protection, etc., which automatically displays the fault point and stops when abnormal.
The equilibrate Conditioning control system (BTHC) is adopted, and the induction system transmits the actual data in the test chamber to the controller. The controller controls the SSR multi-stage intelligent output, and the output power of the equilibrate temperature and humidity system ensures that the temperature and humidity in the test chamber are fully stable and has energy-saving functions. The heating system adopts multi-stage heating pipes with PID modules to ensure temperature stability; the humidification system adopts a circular split humidifier to avoid low temperature freezing; the refrigeration system adopts imported Compressors and environmentally friendly refrigerants to realize forced refrigeration and thermostatic refrigeration segmented control; the air circulation system forces air supply through fans to ensure uniform temperature.
Electronics, electrical appliances, communications, instrumentation, vehicles, plastic products, metals, food, chemicals, building materials, aerospace
1. Connect the power supply to ensure that the voltage meets the requirements. 2. Set the temperature and humidity program through the controller Linear dispersion. 3. Put the sample into the shelf and adjust the layer spacing. 4. Start the instrument and monitor the operating status. 5. After the test is completed, turn off the instrument and remove the sample.
• The use environment temperature should be maintained at 0~ 30 ℃, and the performance guarantee environment is 5~ 25 ℃. • Miscellaneous items cannot be placed within 60CM of the instrument. • Power supply voltage variation allowable value is +/- 10%. • The humidification system has water filtration and needs regular maintenance to avoid blockage. • The instrument has a comprehensive protection system, which automatically stops when abnormal, and needs to deal with the fault in time.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.