Overview
AMITTARI SPT-204-5T is a special instrument for the measurement of cable tension such as wind towers, signal towers, power transmission systems, etc. The product has the advantages of simple operation and easy portability, and provides a variety of test modes to meet different application needs.
Features
1. High Accuracy, high resolution, digital display, ignore the difference.
2. Provide N (newton), kg (kilogram), lb (pound), g (gram) four measurement units, and can be converted to each other.
3. With peak hold function, the peak display can be maintained until manually cleared.
4. Support the use of alkaline batteries or external 5V DC power supply two power supply methods.
Principle
Sensor measures the tension of the rope, converts the force signal into an electrical signal, and displays it digitally on a four-digit LCD screen after internal processing. The instrument has a forward and reverse dual display screen, which can measure and maintain the peak or display the instantaneous value.
Applications
Wind towers, signal transmission towers, power transmission systems
Standards
Level 0.5 accuracy
Steps
1. Select the appropriate installation method according to the measurement requirements and connect the instrument with the rope to be tested.
2. Turn it on and select the force units (kgf, N, Lbf) as required.
3. Conduct a tensile test, and the instrument will display the force value in real time.
4. If you need to record the maximum tension, you can use the peak hold function and manually clear it after testing.
5. After the test is completed, you can choose to shut down manually or wait for 10 minutes to shut down automatically.
Notice
• Do not exceed the allowable load of the instrument at 150% F.s. When the load exceeds 110% F.s., the instrument will emit a beep alarm.
• Please use it in an environment with 0 ° C to 40 ° C and humidity below 80% to ensure that there is no seismic source and corrosive medium around.
• Please use the specified 2 AA alkaline batteries or 5V DC power supply.
• Note that the resolution will change under different ranges, please judge the accuracy according to the displayed value.
• When not in use for a long time, it is recommended to remove the battery.