$ 11247.00Ex works
Adopt sealing solvent system to reduce water vapor interference, support 100 titration methods, Measurement range covers 1ppm to 5%, built-in automatic drift correction function, equipped with electronic adjustment Magnetic Stirrer.
Category : Potentiometric Titrator
Brand : HANNA
SKU : NB045276
Service :The delivery and service By NBCLab.Com
The HI934-02 is a Karl Fischer Coulomb Titrator from the HANNA brand with High Accuracy, Flexibility and repeatability. Designed to perform titration for a wide range of applications, the instrument can analyze water content in the range of 1 ppm to 5%, effectively monitor KF reactions, detect endpoints and perform all necessary calculations and plotting.
1. Small footprint, requires minimal workbench space 2. The shell is made of strong, chemical corrosion resistant plastic 3. Powerful built-in algorithms for termination criteria based on fixed mV endpoints or absolute/relative drift 4. Sample analysis averages and statistics 5. Minimize water vapor entry through a sealing solvent system 6. Balancing interface for automatic weighing 7. Supports 100 titration methods 8. User-defined reports 9. Clear display of warnings and error messages
The HI934-02 uses the Karl Fischer Coulomb Titrimetric method to automatically monitor the KF reaction and detect the endpoint by adjusting the polarization current in the range of 1-10 μA and the voltage range of 2-1100mV. The instrument uses Magnetic Stirrer, electronically adjusts the stirring speed of 200-2000RPM, and realizes High Accuracy titration analysis through a sealing solvent system and built-in algorithms.
Liquid sample analysis, solid sample analysis
1. Preparation of samples (liquid or solid, externally dissolved or extracted) 2. Set the titration method (support 100 methods to choose from) 3. Start pre-titration conditions (automatic) 4. Perform background drift correction (automatic or user selectable) 5. Set endpoint metrics (fixed mV persistence, relative drift stop or absolute drift stop) 6. Select Measurement Speed (Dynamic with 3 Speed Settings) 7. Start titration analysis 8. View result statistics (mean, standard deviation)
• Operating ambient temperature range is 10-40 ℃, relative humidity 80% • Storage ambient temperature range -20 to 70 ℃, relative humidity 95% • Use a sealing solvent system to reduce water vapor ingress • Note Reagent port is standard taper 19 • Titration container operating capacity is 100-200ml • Maximum current is 400mA • Power supply voltage is 100-240VAC, 50/60Hz, 0.5Amps
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.