$ 2363.00Ex works
Simultaneous measurement of 7 water quality paraMeters, turbidity Measurement range 0-50NTU, accuracy +/- 5%, in line with USEPA 180.1 standard, with chroma compensation and Illuminant automatic compensation function, reducing interference without frequent calibrating.
Category : Turbidimeter
Brand : HANNA
SKU : NB045678
Service :The delivery and service By NBCLab.Com
The HANNA HI93102 Turbidity Meter is a Multi-Parameter measurement system that provides rapid measurement of turbidity, chlorine, acidity pH, bromine, iron, iodine, and cyanuric acid (CYAC) for 7 water quality parameters. With a Portable design and laboratory-grade Measurement accuracy, it is widely used in water quality analysis and drinking water quality monitoring.
1. Excellent Optical inspection system design, humanized operation, to ensure that the instrument is well calibrated 2. Manual calibration, built-in standard calibrating point: 0, 20NTU, in line with USEPA method 3. Built-in standard Linear dispersion calibration before leaving the factory, with CAL CHECK performance verification function 4. GLP function, update and consult calibration data, dates, standards and other information at any time 5. Reagent and sample reaction time conformity to ensure Measuring accuracy 6. High Accuracy measurement results, Illuminant dust measurement system, Automatic shutdown power saving mode
The microprocessor calculates the turbidity value by the Light intensity reaching the detector, effectively corrects the Color interference, and has chroma compensation and Illuminant automatic compensation functions to avoid interference caused by Illuminant fluctuations without frequent calibrating. The turbidity measurement adopts the turbidity measurement method (90 ℃) or the scattering turbidity measurement method (90 ℃ & 180 ℃), which conforms to USEPA method 180.1 and standard 2130B.
Water quality analysis, drinking water quality monitoring
USEPA180.1、Standard Method 2130B
1. Manual calibration instrument with built-in standard calibrating point 0 and 20NTU 2. Conduct CAL CHECK performance verification 3. Utilize the GLP function to update and access calibration data, dates, standards, and other information 4. Reagent and sample reaction time conformity measurement
• The instrument is used in an environment of 0 to 50 ° C (32 to 122 ° F), with a maximum relative humidity of 95% and no condensation • Measurement accuracy is affected by temperature, please refer to the accuracy index at 25 ℃ • Powered by 4x1.5V AA battery, pay attention to the automatic shutdown time setting (10, 20, 30, 40, 50, 60 minutes optional) • Avoid Illuminant fluctuation interference, the instrument has automatic compensation function, no need to calibrate frequently
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.