Please contact customer service
Temperature control range + 5 ℃ to 100 ℃, Heating power 2000W, with low liquid level alarm and maintenance-free pressure/suction pump to ensure good Temperature uniformity in the Tank and support internal and external circulation.
Category : Thermostatic Bath
Brand : JingTian
SKU : NB045793
Service :The delivery and service By NBCLab.Com
The RC0508 Super Thermostat is a compact, compact Benchtop thermostatic device with precise temperature control in the room temperature range of + 5 ° C to 100 ° C. It features a high-power heater that quickly reaches and remains stable at set temperatures, a low-level alarm function, and a maintenance-free pressure/suction pump to ensure good temperature uniformity in the tank. It is suitable for temperature control needs in areas such as laboratories and industrial production.
1. Appearance is compact, small size, easy to place on the desktop. 2. When used with Viscometer, the operation and display are convenient, and the test process and data are clear at a glance. 3. The heating power is 2000W, which can easily achieve precise control of any temperature between RT + 15 ° C and 100 ° C. 4. The low-level buoy provides dual alarm with light and sound to prevent dry burning. 5. Maintenance-free pressure/suction pump, pump power is strong, can be horizontal and vertical direction Stir at the same time, good temperature uniformity in the tank, support domestic circulation and external circulation applications. 6. Pump pressure and flow automatically adapt to the external load, using international standard M16x1 connecting nut, can be equipped with different joints to meet the external circulation pipe diameter requirements. 7. Parts that come into contact with liquids or steam are made of high-performance stainless steel and plastics, which are corrosion-resistant and do not scale. 8. Use fluorine-free and environmentally friendly refrigerant R134a. 9. Multiple operation modes are optional, and accidental power failure can be automatically restored. 10. Optional intelligent control function: Provide a variety of interfaces (RS485, RS232) for remote communication, control equipment start and stop; optional 0-10V or 4-20mA analog signal input for external intelligent equipment to control instrument start and stop. 11. With all kinds of Rotational Viscometers produced by our company, viscosity measurement is more convenient and accurate.
The device precisely monitors and regulates the temperature in the tank through an intelligent PID control system and a PT100 temperature transducer. High-power heaters heat up quickly, and maintenance-free pressure/suction pumps circulate the bath solution Stir to ensure even distribution of temperature in both horizontal and vertical directions. The system has the ability to automatically adapt to external loads and is intelligently controlled through a variety of optional interfaces.
Laboratory, industrial production
"JJF 1030-2010 Thermostat technical performance test specification"
1. Place the device on a stable table and connect it to a power supply (200~ 230V, AC/50Hz). 2. Add an appropriate amount of bath liquid to the Tank to ensure that the liquid level is higher than the low liquid level buoy. 3. Turn on the power switch and set the required temperature through the control panel (range: room temperature + 5 ° C to 100 ° C). 4. Start the heating and circulation pump, the equipment starts working, and the LED display displays the real-time temperature. 5. After the temperature reaches the set value and stabilizes, relevant experiments or tests can be carried out. 6. After use, turn off the heating and pump, and disconnect the power supply. 7. For external circulation, connect the corresponding pipeline to the M16x1 interface and configure the appropriate connector.
• Make sure the Ambient Temperature is within the range of 5~ 32 ℃ before use. • Be sure to keep the liquid level in the Tank sufficient to avoid triggering a low liquid level alarm or causing dry burning. • When making external circulation connections, make sure that the pipeline connections are firm to prevent leakage. • When the equipment is running, do not touch the heating parts and high-temperature bath liquid to prevent burns. When cleaning and maintaining, please disconnect the power supply first. • Do not use power frequencies that do not meet the regulations. • If not used for a long time, please empty the bath liquid and keep the equipment drying.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.