Overview
LeiEn LN-60K Furnace temperature tracker for semiconductor curing is a temperature monitoring device specially designed for semiconductor manufacturing processes. It operates safely and stably in high temperature environments through superior thermal insulation performance, tracks and records the temperature status of heating furnaces and products throughout the process, and generates temperature Linear dispersion analysis reports to help engineers optimize process parameters, improve product quality, achieve stable production and high yield and save energy.
Features
1. High Accuracy measurement: It can accurately measure the temperature in the furnace and provide accurate temperature data.
2. Fast Response: It can quickly detect temperature changes and feed back to the Process Control system in time.
3. Wide Temperature range: Temperature range required to adapt to different semiconductor processes, from low temperature to high temperature can be measured.
4. Reliability: Durability and Stability, able to work long hours in harsh industrial environments.
5. Data logging and analysis functions: Temperature data can be recorded and analyzed to help engineers optimize process parameters.
Principle
The LeiEn LN-60K Furnace temperature tracker and the product track and record the temperature status of the heating furnace and the product through the heating furnace, obtain multi-directional accurate data and form a temperature Linear dispersion analysis report. The analysis software performs various Data analysis calculations, and accurately optimizes the heating furnace parameters through the results.
Applications
UV furnace semiconductor curing Furnace temperature tracker, vacuum furnace Furnace temperature tracker, non-stick Coating Furnace temperature tracker, non-stick pan temperature tester, Dacromet Furnace temperature tracker, muffle furnace temperature tester, painting paint furnace temperature tester, steel heat treatment Furnace temperature tracker, wheel hub heat treatment Furnace temperature tracker, wave soldering reflow furnace temperature tester, car painting Furnace temperature tracker, food stoving Furnace temperature tracker, ceramic firing Furnace temperature tracker, Glass roasting annealing furnace temperature tester, special custom furnace temperature tester
Steps
1. Put the furnace temperature tester into the heating furnace together with the product.
Set the sampling rate (e.g. 1s, 2s, etc.) and recording parameters.
3. Start the test, and the instrument automatically tracks and records the temperature data.
4. Connect the instrument through the computer, download the data and generate the temperature Linear dispersion and analysis report.
5. Optimize the heating furnace process parameters according to the analysis results.
Notice
• Ensure that the insulation box is used within the specified Temperature range (-50-200 ℃).
• Choose the appropriate sampling rate and recording time according to actual needs.
• Regularly check instrument durability and Stability in harsh industrial environments.
• Use a K-type Thermocouple Sensor to ensure accuracy of +/- 0.3 ° C.
• The material of the heat insulation box is high temperature resistant 310S stainless steel and nano aerospace environmentally friendly materials to avoid damage due to improper operation.