Overview
The TENLIN DC-4020 (RWD100) Vertical Low Temperature Circulating Bath is a precision thermostatic device with a Tank volume of 20L with a Temperature range of -40 ° C to 100 ° C. It uses self-developed temperature control technology, with High Accuracy Temperature Control and multiple Safety protection functions, suitable for various experiments and tests requiring stable low temperature or thermostatic environment.
Features
1. Adopt self-developed temperature control technology, equipped with High Accuracy PT100 Sensor and imported electronic components.
2. The software system can correct the error between the displayed temperature and the actual temperature to ensure accurate display.
3. Standard large-screen LCD display, Temperature Display resolution up to 0.01 ℃.
4. With over-temperature protection and alarm function, the alarm temperature can be set and the load can be automatically cut off.
5. With timing function, the total Operating Time of the equipment can be set, and the load can be automatically cut off at that time.
6. Adopt hidden chilled down coil design to increase the effective use space in the groove.
7. Intelligent Software Temperature Stability, PID can automatically adjust parameters, also supports manual adjustment.
8. Software Digital Lock Control system settings to prevent misoperation and ensure accurate experimental data.
9. The fully enclosed Compressor is used for refrigeration, with fast cooling speed and multiple protections such as overheating and overcurrent.
10. Standard internal and external circulation function, external circulation interface for the outer diameter of 10mm round tube.
11. Support non-standard customization services.
Principle
The Thermostatic bath monitors the medium temperature in the tank in real time through the High Accuracy PT100 Sensor, and transmits the signal to the Control system. The Control system uses an intelligent PID algorithm to automatically adjust the working status of the heater and the fully enclosed Compressor refrigeration system according to the difference between the set temperature and the measured temperature, so as to achieve fast and accurate temperature control. At the same time, the system ensures that the displayed temperature is consistent with the actual temperature through the software correction function, and promotes the Temperature uniformity of the medium in the tank and the external circulation pipeline through the internal and external circulation pumps.
Applications
Application is not explicitly mentioned in the information provided.
Standards
The compliance criteria are not explicitly mentioned in the information provided.
Steps
The steps are not explicitly mentioned in the information provided.
Notice
Notes are not explicitly mentioned in the information provided.