Overview
BH-90M-H2S is a single Gas detector of BOSEAN brand, using industrial grade Sensor and micro control technology, with Fast Response, High Accuracy measurement ability, Stability and Repeatability. The product design is inspired by pebbles, Appearance is round, small and durable, the shell is made of high strength engineering plastic and covered with composite anti-skid rubber, which has waterproof, dustproof and explosion-proof characteristics. Gas detection by natural diffusion method, Sensitivity and Repeatability are good, easy to use and maintain, and meet the high Reliability requirements of industrial site safety monitoring.
Features
1. Industrial Sensor and Micro Control Technology for Fast Response and High Measurement accuracy
2. The design is round and compact, the shell is high-strength engineering plastic covered with anti-skid rubber, which is durable and feels good
3. With waterproof, dustproof and explosion-proof multiple protection functions
4. Natural Diffusion Detection with Excellent Sensitivity and Repeatability
5. Easy to use and maintain, to meet the high Reliability requirements of industrial sites
Principle
Gas detection is carried out by natural diffusion, using industrial-grade Sensor and micro-control technology implementation Fast Response and High Accuracy measurement. Its advanced large-scale integrated circuit meets international intelligent technical standards to ensure Sensitivity and Repeatability of detection.
Applications
Petroleum, chemical industry, environmental protection, metallurgy, refining, gas transmission and distribution, agriculture, explosion-proof, toxic gas leakage rescue, underground pipelines, mines, metallurgy, power plants, chemical industry, tunnels, tunnels
Standards
GB3836.1—2010、GB3836.4—2010、GB12358—2006、GB15322.3—2019、JJG693—2011、JJG365—2008、JJG695—2019、JJG915—2008
Steps
1. Turn on the power and start the detector.
2. Read real-time gas concentration data through LCD display
3. Determine the alarm status according to the sound, vibration or Light Emitting Diode indication
4. Charge in time after use to ensure that the battery is fully charged
Notice
• Ambient Temperature should be kept within -10~ 55 ℃
• Environmental humidity should be less than 95% RH and no condensation
Avoid prolonged use in extreme environments
• Regularly check the life of the Sensor, usually about 2 years
• Ensure that the battery is fully charged and the continuous use time is not less than 8 hours
• It takes 4 to 6 hours to complete charging