Using industrial grade Sensor, Response Time T90 < 60 seconds, with waterproof, dustproof and explosion-proof function, high-strength engineering plastic shell covered with anti-skid rubber, small and durable and supports sound and light vibration alarm.
Category : Gas Detector
Brand : Bosean
SKU : NB047004
Service :The delivery and service By NBCLab.Com
BH-90M-Xylene/toluene is a single Gas detector under the BOSEAN brand. The product uses industrial-grade Sensor and micro-control technology, with the characteristics of Fast Response, High Accuracy measurement, excellent stability and repeability. Its design is inspired by pebbles, Appearance is round and small, the shell is made of high-strength engineering plastic and covered with composite anti-skid rubber, with waterproof, dustproof and explosion-proof characteristics, good feel and strong durability. Sensitivity and repeability are high, easy to use and maintain, and can meet the needs of industrial site safety monitoring for high reliability of equipment.
1. Industrial Sensor and Micro Control Technology for Fast Response and High Measurement Accuracy. 2. Excellent stability and repeability, reaching the advanced level of the industry. 3. Smooth and round pebble-inspired design, no edges and corners, good durability. 4. The shell is made of high-strength engineering plastic and composite anti-skid rubber, with high strength and good feel. 5. With multiple protection functions of waterproof, dustproof and explosion-proof. 6. Sensitivity and repeability are good with natural diffusion detection. 7. Easy to use and maintain, to meet the high reliability monitoring needs of industrial sites. 8. Equipped with LCD data display, sound and light vibration alarm and low battery prompt function.
The gas detector uses natural diffusion for gas detection. The gas enters the instrument through natural diffusion and reacts with the built-in industrial-grade Sensor, which converts the gas concentration signal into an electrical signal. The microcontroller processes and analyzes the electrical signal, and finally displays the gas concentration value in real time on the LCD screen. When the concentration exceeds the preset alarm point, the instrument will issue an alarm through Light Emitting Diode, sound and vibration.
Petroleum, chemical industry, environmental protection, metallurgy, refining, gas transmission and distribution, agriculture, explosion-proof places, toxic gas leakage rescue, underground pipelines, mines, power plants, tunnels, tunnels
GB3836.1 - 2010 "Explosive environment Part 1: General requirements for equipment", GB3836.4 - 2010 "Explosive environment Part 4: Equipment protected by intrinsically safe" i ", GB12358 - 2006" General technical requirements for workplace environment Gas detection alarms ", GB15322.3 - 2019" Combustible gas detectors Part 3: Portable combustible gas detectors for industrial and commercial use ", JJG693 - 2011" Combustible Gas detection alarm verification regulations ", JJG365 - 2008" electrochemistry oxygen detector verification regulations ", JJG695 - 2019" Hydrogen sulfide gas detector verification regulations ", JJG915 - 2008" Carbon monoxide detection alarm verification regulations "
1. Power on: Long press the power button to start the instrument. 2. Self-test: Conduct self-test after the instrument is started to observe whether the display and status indicator are normal. 3. Detection: The instrument is placed in the environment to be tested and the gas concentration is detected by natural diffusion. 4. Reading: Real-time gas concentration data (in ppm) is read on the LCD screen. 5. Alarm Response: When the concentration exceeds the standard, the instrument will issue sound and light vibration alarm, and corresponding measures need to be taken according to the safety procedures. 6. Shutdown: Long press the power button to turn off the instrument. 7. Charging: When the battery is low, use the matching charger to charge the built-in lithium battery, which lasts about 4-6 hours.
* Do not use in an environment that exceeds the specified temperature (-10~ 55 ° C) and humidity (< 95% RH without condensation). * The instrument is designed to be explosion-proof (ExibIICT4Gb), but it is still necessary to avoid abuse in extremely dangerous environments. * Alarm point can be manually set as needed, different gas default alarm point is different, please do not change at will. * Sensor life is about 2 years, the actual life depends on the specific Operating Environment, requires regular maintenance or replacement. * Please use the original or designated charger when charging, and ensure the safety of the environment. * The continuous Operating Time of the instrument is not less than 8 hours, please pay attention to the power prompt and charge it in time. Avoid severe impact or immersion of the instrument in liquids to prevent damage. Periodically calibrate instruments according to relevant verification procedures to ensure measurement accuracy.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.