Please contact customer service
Temperature range -20~ 40 ℃, Temperature Stability up to +/- 0.5K. Proportional cooling and PID control technology, equipped with semi-enclosed water Tank and corrosion resistant stainless steel material, support a variety of temperature settings and operation modes, circulating pump pressure Flow rate adjustable.
Category : Thermostatic Bath
Brand : labtop
SKU : NB047383
Service :The delivery and service By NBCLab.Com
The iCoolero-2020E Cryogenic coolant circulating pump is an advanced device specially designed for chilling down liquid circulation at low temperatures. It uses a waterproof keyboard and a high-brightness TFT display, which has high display accuracy and can indicate the running status in real time. The device combines proportional cooling and PID control technology to ensure that the temperature Stability reaches +/- 0.5 ° C, and supports a variety of temperature setting methods. Equipped with a semi-enclosed water tank and corrosion-resistant stainless steel material, it is suitable for a variety of application scenarios such as large Rotary evaporator, Reaction Kettle system, Bioreactor, etc. It has the characteristics of high performance and stability.
1. Waterproof keyboard design, high-brightness TFT display, display accuracy 0.1, the operation panel can indicate heating, cooling, circulation, external temperature control various operating states. 2. Refrigeration and circulation can be automatically started with one click, and the cycle can also be started and stopped with one click alone. 3. Three temperature setting methods: the setting temperature can be increased or decreased by 0.1 degrees by pressing the button; it can also be quickly increased or decreased by long pressing the button; it supports fast cursor movement to directly change the setting value. 4. Combination of Proportional Refrigeration and PID Control Technology, More Energy Saving, Temperature Stability +/- 0.5 ℃. 5. A semi-enclosed water tank design with an intuitive liquid level window and a protective overflow port. 6. Immersion pressure suction pump, mixing the liquid in the tank evenly, high heat exchange efficiency, can be closed or open external circulation applications, to achieve a multi-functional machine. 7. Flow rate of circulating pump is large and does not damage Glass components. Rotation speed of pump is adjustable, so as to realize adjustable pressure, suction and Flow rate. 8. Using corrosion-resistant SUS304 stainless steel water tank and chilled down coil, long-term use does not produce patina and rust. 9. Three operation modes can be set: two automatic start operation modes and one manual operation button start mode. 10. The circulating water system adopts a multiple water purification design to prevent impurities from entering the pump system and prolong the service life of the pump. 11. The buzzer can be set to silent or audible mode. 12. Using high-performance and high-mass spare parts, the system is stable and reliable. 13. Use environmentally friendly refrigerants without toxic pollution. 14. The maximum and minimum temperature settings of the machine can be limited. 15. With multiple safety protection: system over-temperature protection, high and low temperature protection, overheating and overcurrent protection; liquid system can be protected by water pressure, pipeline blockage protection; alarm lights and sounds remind at the same time, and directly display the alarm code to determine the error point.
The device drives chilled down fluid through the system's domestic circulation via an immersion pressure suction pump. Combining proportional refrigeration technology and PID control algorithms, the refrigeration output is precisely adjusted to achieve and maintain the set target temperature. The chilled down fluid is heat exchanged in corrosion resistant stainless steel coils and tanks. Rotation speed of the pump is adjustable to control the pressure, suction and Flow rate of the cycle, thus efficiently providing chilled down to external equipment.
Rotary evaporator chilling down, medium and large Reaction Kettle system, medium and large Bioreactor, biological fermentation tank, distillation system, Evaporator, extractor, condensation reflux device, etc
Not mentioned
1. Select the running mode according to your needs (two power-on automatic start modes or manual button start modes). 2. To set the target temperature through the waterproof keyboard, three ways can be used: the keys are increased or decreased in 0.1 degree steps, long press to increase or decrease quickly, or the cursor is moved quickly to enter directly. 3. Start the refrigeration and circulation function with one click, or start/stop the circulation function separately. 4. Monitor the operation status of heating, cooling, circulation, and external temperature control by observing the TFT display and high-brightness indicator. 5. Observe the water tank level through the liquid level window to ensure that it is within the normal range. 6. According to the requirements of external equipment, adjust the Rotation speed of the circulating pump to control the pressure, suction and Flow rate. 7. After use, press operation to stop the device.
• Before use, make sure that the Power supply voltage is 220V/50Hz, and check whether the equipment is well grounded. Equipment operating environment allows a relative humidity of 5% to 32%, do not use in an environment beyond this range. • Please regularly observe the liquid level chilled down through the liquid level window to ensure that the liquid level is normal and prevent low liquid level operation (optional low liquid level alarm function). • The size of the external circulation interface is RC1/2 (4 points inner teeth). Please ensure that it matches and is firm when connecting the external pipeline to avoid leakage. • Flow rate and pressure of circulating pump are adjustable. When connecting vulnerable components such as Glass, it is recommended to start adjusting from low Flow rate/pressure to avoid damage. • The equipment is equipped with a protective overflow port, do not block, and ensure that the equipment is well ventilated around. • When the equipment emits a sound and light alarm and displays an alarm code, please check the corresponding error points (such as over-temperature, pipeline blockage, etc.) according to the code prompts, and then run after troubleshooting. • The equipment is heavy (114kg), so pay attention to safety when moving and installing to prevent dumping. • Optional heating function, RS232/USB Communication interface and low liquid level alarm function, please choose according to actual needs. • Use equipment-specified or compatible chilled down fluid and maintain water quality regularly through multiple purification systems to extend pump life. • Non-professionals should not disassemble or repair the internal parts of the equipment.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.