Overview
The side pressure tension meter (model: DB25-204SPT 100KN) is a digital and explicit tension meter newly designed and developed by DUBAN brand, which is mainly used for the measurement of the tension of ropes such as wind towers, signal towers, and power transmission systems. The instrument has the advantages of High Accuracy, easy operation, and easy portability, and is equipped with various test modes such as peak hold, which is convenient for users to use. Users can choose the corresponding specifications according to the size of the test force value, and the scientific test range is 10% to 100% of the full scale.
Features
1. High Accuracy and high resolution.
2. Numbers show, ignoring the difference.
3. N (newton), kg (kilogram), lb (pound) three measurement units are available for selection and conversion.
4. Peak hold function. Keep peak display until manually cleared.
5. Dual power supply mode: can use alkaline battery power supply; can also be connected to 5V DC power supply.
6. Dual display design makes it easy to read data in multiple directions.
7. With overload alarm function (over 110% F.s, there is a beep alarm).
Principle
The instrument receives the force information through the measurement Sensor and converts it into an electrical signal and transmits it to the host. The host processor processes the signal, and finally displays the measurement reading, units and related prompt information in digital form on the display.
Applications
Wind tower, signal transmission tower, power transmission system and other rope tension measurement
Steps
1. Connect the host and Sensor according to the test requirements.
2. Select the power supply method (install the battery or connect the 5V DC power supply).
3. After the instrument and the object to be tested are in place, press the ZERO button to clear before starting the test to eliminate the weight of the fixture.
4. When testing, the instrument can display peak or instantaneous values.
5. After the test is completed, you can shut down manually or wait for 10 minutes to shut down automatically.
Notice
Scientific use of the test range of 10% to 100% of full scale, Measurement Department recommends not to use less than 1% of full scale.
* Before starting the test after the instrument and the test object are in place, be sure to press the ZERO button to clear.
The allowable load is 150% F.s, and when it exceeds 110% F.s, the instrument will emit a beep alarm.
* operating temperature: 0 ℃~ 40 ℃.
* operating humidity: < 80%.
* Working environment: there should be no source and corrosive medium around.
* Note that resolution varies according to different force units and range.