Overview
Universal Testing Machine UTTM4-DB25-204FM-20N is a small, simple, multi-functional, High Accuracy thrust and tensile testing instrument. It is widely used in Electronics, Construction Hardware, Light Industry Spinning & Weaving, Auto Parts, Lighters and other ignition devices, fire equipment, pens, locks, fishing gear, chemical industry, power machinery, scientific research institutions and other industries, for push-pull load, insertion force test and Destructiveness test.
Features
1. High Accuracy and high resolution, digital display ignores poor.
2. Provide four measurement units: N (newton), kg (kilogram), lb (pound), and g (gram), which can be converted into each other.
3. With peak hold function, the peak display can be maintained until manually cleared.
4. It can be set to shut down automatically without operation for 10 minutes, or it can be shut down manually.
It can be powered by alkaline battery or 5V DC power supply.
6. Equipped with a blue backlit display.
7. With overload alarm function (buzzer alarm when exceeding 110% range).
Principle
Sensors measure the force applied to the test sample, and convert the force signal into an electrical signal, which is processed and displayed digitally on the LCD screen. Users can select Real-time Measurement mode or Peak Hold mode to read the instantaneous force value or the maximum force value.
Applications
Push-pull load, insertion force test, Destructiveness test of terminals, wires, ropes, plastics, films, rubber, fabrics, fishing lines, respirators and other materials
Standards
The data did not mention specific compliance criteria
Steps
1. Press the "POWER/EXIT" button to turn it on.
2. Use the "Units key (UNIT) " to select the desired force unit (N, kg, lb, g).
3. When no external force is applied, press the "ZERO button" to correct the instrument.
4. Press "PEAK" to switch between Peak Hold mode and Real-time Measurement mode.
5. Test the force applied to the sample and read the force value (instantaneous value or peak value) from the display screen.
6. After the test is completed, press the "Power/Return button (POWER/EXIT) " to shut down, or wait 10 minutes for automatic shutdown.
Notice
* Do not use the instrument with more than 150% of the full scale (F.s) load, the instrument will issue a buzzer alarm when it exceeds 110% of the range.
* Please use it in an environment with a temperature of 0 ° C to 40 ° C and a humidity of less than 80%.
* Please ensure that there are no sources and corrosive media around the working environment.
The zero correction operation should be performed when no external force is applied.
* Optional to use 2 AA alkaline batteries or 5V DC power supply.
The instrument has a 10-minute automatic shutdown function without operation, and can also be shut down manually.