Overview
Universal Testing Machine UTTM7-DB25-204FM-20N is a small, simple, multi-functional, High Accuracy thrust and tensile testing instrument. It is widely used in Electronics, Construction Hardware, Light Industry Spinning & Weaving, Auto Parts, Lighters and other ignition devices, fire equipment, pens, locks, fishing gear, chemical industry, power machinery, scientific research institutions and other industries for push-pull load, insertion force test and Destructiveness test.
Features
1. High Accuracy and high resolution, digital display ignores poor.
2. Provide four measurement units: N (newton), kg (kilogram), lb (pound), and g (gram), which can be converted into each other.
3. With peak hold function, the peak display can be maintained until manually cleared.
4. It can be set to automatically shut down without operation for 10 minutes, and manual shutdown is also supported.
5. It can be powered by alkaline battery or connected to 5V DC power supply.
Principle
Sensors measure the force applied to the object under test, and convert the force signal into an electrical signal, which is displayed digitally on the four-digit LCD screen after processing. Users can choose the peak hold mode or the real-time test mode, and the instrument can accurately record and display the maximum force value or instantaneous force value during the test process.
Applications
Terminals, wire, rope, plastic, film, rubber, fabric, fishing line, respirator, etc
Steps
1. Use the power/return key (POWER/EXIT) to power on.
2. Use the zero correction key (ZERO) to calibrate the instrument.
3. Use the Units key (UNIT) to select the desired force unit (N, kg, lb, g).
4. Use the peak key (PEAK) to switch between peak hold mode or live test mode.
5. Conduct the test and the readings will be displayed on the screen.
6. In peak mode, the peak will remain displayed and can be manually cleared by pressing the Miscellaneous key.
7. When you need to save data, press the Save/Add key (SAVE/▲).
8. Press the read/subtract key (READ/T) to enter the data browsing mode to view the stored data, and use the save/add key (SAVE/▲) and the read/subtract key (READ/T) to browse up and down.
9. Press the Delete key (DEL) to delete the saved data.
10. Long press the power/return button (POWER/EXIT) to shut down, or wait for automatic shutdown.
Notice
* The allowable load of the instrument is 150% F.s. If it exceeds 110% F.s, there will be a beep alarm. Please do not overload it for a long time.
* Please ensure that there are no sources and corrosive media around the working environment.
* Operating temperature range is 0 ℃~ 40 ℃, Operating humidity should be less than 80%.
* Please use the specified 2 AA alkaline batteries or 5V DC power supply.
In data browsing mode, the POWER/EXIT key can be used as the return key.
* When setting the automatic shutdown time, you need to use the read/subtract key (READ/T) and the save/add key (SAVE/▲) to convert the settings.