Please contact customer service
With 0.001 pH High Accuracy resolution and ≥ 3 × 1012 Ω input Impedance, supports 5 Measurement modes and 8 groups of 37 pH standard solutions for automatic identification, IP65 protection ensures stable outdoor operation.
Category : pH Meter
Brand : FZchina
SKU : NB047886
Service :The delivery and service By NBCLab.Com
The FANGZHOU PHBJ-360F Portable pH Meter is a High Accuracy measuring instrument suitable for out-of-home measurement of sample pH value. It can stably and accurately measure pH, mV, ORP, T values of 98% of samples. It uses a large-screen LCD display, supports backlight adjustment and menu navigation operation, and has a built-in intelligent Operating system. It has a variety of management functions, complies with GLP standards, and supports data traceability and statistical analysis.
1. Large-screen LCD display, support backlight adjustment, table display and menu navigation operations 2. Support Chinese and English language interface 3. Temperature units are available in 3 types: Celsius (° C), Fahrenheit (° F), thermodynamic temperature (K). 4. With functions such as power-on self-diagnosis, regular automatic shutdown, power-off protection and factory reset 5. Support IP65 Protection Ratings 6. Standard 3 composite Electrode, optional special Electrode, accurate and stable measurement of pure water, soil, trace samples and other difficult samples 7. Intelligent Operating system, support method setting, Electrode management, calibrate management, sample management and user management 8.0.001pH/0.01mV High Accuracy resolution, ≥ 3 × 1012Ω High Input Impedance Design 9. Allow users to set user IDs, sample IDs, support hierarchical permissions and password management 10. Support measurement of pH, mV, RelmV, ORP, T value 11. Built-in reference Electrode with 6 different structural configurations 12. Automatic identification of 8 groups of 37 pH standard solutions, up to 5 points calibrated 13. ATC automatic identification, automatic/manual temperature compensation 14. Five Measurement modes: Manual reading, Automatic fast reading, Automatic medium speed reading, Automatic slow reading, Timed reading 15. Support ORP Electrode calibrated and 2 pH calibrated fitting methods 16. Dual clock and date display, support timing storage function 17. Data management functions to access current and historically calibrated data and store no less than 10,000 sets of data 18. Compliant with GLP standards, supports USB interface to export data to computer 19. Powered by large-capacity lithium battery, supports mobile power supply and PC charging, with battery power display and charging status reminder
The PHBJ-360F Portable pH Meter converts to pH value by built-in high-input Impedance design (≥ 3 × 1012Ω) and composite Electrode to detect hydrogen ion concentration in samples. It supports automatic temperature compensation (ATC), which automatically or manually adjusts temperature effects to ensure measurement accuracy. The instrument uses an intelligent calibrating system that automatically recognizes multiple standard fluids, optimizes measurement accuracy through multi-point calibrating, and supports ORP and temperature measurement at the same time for Multi-Parameter stable detection.
Ultrapure water, pure water, Waterborne resin, waterborne paints, plaster powder, Titanium Dioxide, soil, protein, enzyme solution, TRIS buffer, PBS buffer, strong acid, strong alkali, wastewater, surface water, tap water, drinking pure water
GLP
1. Power-on self-diagnosis, check the status of the instrument 2. Select Measurement mode (manual reading, automatic fast reading, automatic medium speed reading, automatic slow reading or timed reading) 3. Electrode calibrating, automatic identification of standard liquid, up to 5 points calibrating 4. Set the sample ID and user ID, adjust the temperature unit and language interface as needed 5. Immerse Electrode in the sample and begin measurement of pH, mV, ORP or T 6. Data is automatically stored and can be exported to the computer through the USB interface 7. Shut down after use, support regular automatic shutdown function
• Electrode cleaning before use to avoid contamination affecting Measurement accuracy • When calibrating, use the standard solution automatically recognized by the instrument to ensure that the calibrating point covers the range of 1.09pH to 12.75pH • When measuring high viscosity or low Ion concentration samples, it is recommended to use special Electrode to improve Stability • Regularly check the battery power and charge it in time to avoid power failure affecting the operation • Pay attention to the timing setting when storing data, the range is between 5-3600 seconds • Confirm that the USB connection is stable before exporting data to prevent data loss Avoid prolonged use in extreme temperature environments to protect instrument performance
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.