$ 7164.00Ex works
Temperature range -30 to 600 ℃, equipped with High Sensitivity Sensor and dual mode temperature control system, supports 12-step program temperature control and 1-10Hz sampling Frequency, with independent atmosphere control and multi-point temperature correction function.
Category : Other Instruments
Brand : HuiCheng
SKU : NB048378
Service :The delivery and service By NBCLab.Com
Huicheng DSC-600C/-30~ 600 Differential Scanning Calorimeter is a heat flow Differential Scanning Calorimeter. It adopts the classical thermal analysis method of thermal effect at controllable program temperature and is widely used in research and development, process optimization, Quality control and failure analysis in the field of materials and chemistry. The instrument is used for the measurement of physical and chemical changes related to heat, such as Glass transition temperature, melting point, crystallization heat, phase transition reaction heat, thermal stability, curing/crosslinking and oxidation induction period.
1. The integrated design of the whole machine reduces signal loss and interference, improves signal sensitivity and resolution, and obtains a more stable Baseline. 2. Equipped with imported high-frequency core control processor, the operation processing speed is fast, and the control is efficient. 3. Adopt Imported High Sensitivity Sensor to Improve Sensitivity and Accuracy of DSC Signal. 4. Independent atmosphere control, intelligent software settings, and automatic switching of the instrument's gas path system improve experimental efficiency. 5. The lower computer and the upper computer of the equipment system have multi-point temperature correction function at the same time to improve the accuracy of temperature testing. 6. With two experimental modes of FTC and STC, the temperature control is friendly and flexible, meeting the needs of different application scenarios, accurate temperature control, and efficient Sensor signal analysis. 7. The full temperature control system adopts an optimized dynamic PID algorithm to avoid the shortcomings of traditional PID and improve the robustness of dual-mode temperature control. 8.12-Order program temperature control settings, experimental methods are diverse. 9. Sensor signal sampling Frequency 1~ 10Hz can be set, the experimental method is flexible, and the data is controllable. 10. Independent of each other dual temperature sensor, while separately testing the furnace temperature and sample temperature. 11. The equipment system can be used for heating, cooling, and isothermal related material experiments. 12. The instrument adopts USB two-way communication, supports self-recovery connection, intelligent software design, has Baseline deduction function, automatic drawing of experimental process, intelligent processing data such as enthalpy calculation, Glass transition temperature, oxidation induction period, material melting point and crystallization, etc.
Differential Scanning Calorimetry (DSC) is a classical thermal analysis method that studies the thermal behavior of materials by measuring the difference in heat flow between the sample and the reference substance. The instrument detects the change of the thermal effect of the sample during the heating, cooling or isothermal process under the program temperature control to analyze the physical and chemical transitions.
Inorganic materials, polymer materials, oils and other foods
Equipped with standard materials, users can adjust the temperature and enthalpy by themselves
1. Intelligent setting of experimental parameters through software, including atmosphere control, programmed temperature control, etc. 2. The instrument automatically switches the gas path system to conduct experiments. 3. During the experiment, the system automatically plots and processes the data. 4. Use multi-point temperature correction to calibrate.
• Operating voltage is AC220V/50Hz or custom voltage. • Gas flow rate is controlled at 0~ 200mL/min, gas pressure is 0.2Mpa. • Temperature and enthalpy correction were performed using standard materials before the experiment. • Note that the Sampling rate setting range is 1~ 10Hz. • Follow the range of heating rate 0.1 to 100 ° C/min and cooling rate 0.1 to 50 ° C/min.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.