$ 8949.00Ex works
Temperature range -40~ 600 ℃, DSC resolution 0.01μW, support FTC and STC experimental mode, 12-order program temperature control and dual atmosphere automatic switching, improve Test accuracy and experimental flexibility.
Category : Other Instruments
Brand : HuiCheng
SKU : NB048379
Service :The delivery and service By NBCLab.Com
Huicheng DSC-600C/-40~ 600 Differential Scanning Calorimeter is a heat flow Differential Scanning Calorimeter. It adopts the thermal effect analysis method under controllable program temperature and is widely used in the research and development, process optimization, Quality control and failure analysis of materials and chemistry. The instrument can measure physical and chemical changes related to heat, such as Glass transition temperature, melting point, crystallization heat, phase transition reaction heat, thermal stability, curing/crosslinking, oxidation induction period, etc.
1. The integrated design of the whole machine reduces signal loss and interference, improves signal sensitivity and resolution, and obtains a more stable Baseline. 2. Equipped with imported high-frequency core control processor, the operation processing speed is fast, and the control is efficient. 3. Adopt Imported High Sensitivity Sensor to improve DSC signal sensitivity and accuracy. 4. Independent atmosphere control, intelligent software settings, and automatic switching of the instrument's gas path system improve experimental efficiency. 5. The lower computer and the upper computer have multi-point temperature correction function to improve the accuracy of temperature testing. 6. Available in FTC and STC experimental modes, temperature control is friendly and flexible, meeting the needs of different application scenarios, with accurate temperature control and efficient signal analysis. 7. The full temperature control system adopts an optimized dynamic PID algorithm to improve the robustness of dual-mode temperature control. 8.12-Order program temperature control settings, experimental methods are diverse. 9. Sensor signal sampling Frequency 1~ 10Hz can be set, the experimental method is flexible, and the data is controllable. 10. Independent dual temperature sensors can simultaneously test the temperature of the furnace body and the temperature of the sample. 11. The equipment system can be used for heating, cooling, and isothermal related material experiments. 12. The instrument adopts USB two-way communication, supports self-recovery connection, intelligent software design, has Baseline deduction function, automatic drawing of experimental process, intelligent data processing, such as enthalpy calculation, Glass transition temperature, oxidation induction period, melting point and crystallization.
Differential Scanning Calorimetry (DSC), a classical thermal analysis method for thermal effects at controlled programmed temperatures, studies the thermal performance of materials by measuring the heat flow difference between the sample and the reference during programmed temperature control. The instrument uses a high-Sensitivity Sensor to detect heat flow signals, combined with a dynamic PID algorithm and intelligent atmosphere control to achieve accurate temperature control and data collection.
Inorganic material phase transition, polymer material melting, crystallization process, oil and other food solid/liquid phase ratio
Equipped with standard materials, users can adjust the temperature and enthalpy by themselves
1. Intelligent setting of experimental parameters through software, including heating rate, cooling rate, atmosphere control, etc. 2. The instrument automatically switches the gas path system and starts the experiment. 3. During the experiment, the system automatically plots and collects data. 4. After the experiment, the software intelligently processes the data to calculate the enthalpy, Glass transition temperature, etc.
• Operating voltage AC220V/50Hz or custom voltage to avoid power mismatch. • Gas flow rate is controlled at 0~ 200mL/min, and the gas pressure does not exceed 0.2Mpa. • Check instrument calibration before use to ensure temperature and enthalpy accuracy. • Pay attention to the atmosphere control setting during the experiment to avoid gas path errors. • Sampling rate settings need to be adjusted within the range of 1~ 10Hz according to experimental requirements.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.