$ 9379.00Ex works
Adopt imported High Sensitivity Sensor to improve signal accuracy, with FTC and STC dual experimental mode and 12-order program temperature control, Temperature resolution up to 0.01 ℃, support dual atmosphere automatic switching and 1~ 10Hz sampling Frequency settings.
Category : Other Instruments
Brand : HuiCheng
SKU : NB048380
Service :The delivery and service By NBCLab.Com
Huicheng DSC-600L/-100~ 600 Differential Scanning Calorimeter is a thermal flow Differential Scanning Calorimeter. It adopts the thermal effect analysis method at controllable program temperature and is widely used in the research and development, process optimization, Quality control and failure analysis of materials and chemistry. The instrument can measure physical and chemical changes related to heat, such as Glass transition temperature, melting point, crystallization heat, phase transition reaction heat, thermal stability, curing/crosslinking and oxidation induction period.
1. The integrated design of the whole machine reduces signal loss and interference, improves signal sensitivity and resolution, and obtains a more stable Baseline. 2. Equipped with imported high-frequency core control processor, the operation processing speed is fast, and the control is efficient. 3. Adopt Imported High Sensitivity Sensor to Improve Sensitivity and Accuracy of DSC Signal. 4. Independent atmosphere control, through software intelligent settings, the instrument automatically switches the gas path system, resulting in high experimental efficiency. 5. The lower and upper computers of the equipment system have multi-point temperature correction functions to improve the accuracy of temperature testing. 6. Available in FTC and STC experimental modes, temperature control is friendly and flexible, meeting the needs of different application scenarios, with accurate temperature control and efficient signal analysis. 7. The full temperature control system adopts an optimized dynamic PID algorithm to avoid the shortcomings of traditional PID and improve the robustness of dual-mode temperature control. 8.12-Order program temperature control settings, experimental methods are diverse. 9. Sensor signal sampling Frequency 1~ 10Hz can be set, the experimental method is flexible, and the data is controllable. 10. Independent dual temperature sensors can simultaneously test the temperature of the furnace body and the temperature of the sample. 11. The equipment system supports heating, cooling, and isothermal related material experiments. 12. The instrument adopts USB two-way communication, supports self-recovery connection, intelligent software design, has Baseline deduction function, automatic drawing of experimental process, intelligent processing data such as enthalpy calculation, Glass transition temperature, oxidation induction period, melting point and crystallization.
Differential Scanning Calorimetry (DSC) is a classical thermal analysis method that studies the thermal performance of materials by measuring the heat flow difference between the sample and the reference substance. Under program temperature control, the instrument detects the thermal effects of the sample during physical or chemical changes, such as phase transition, melting, crystallization, etc., to obtain relevant thermodynamic parameters.
Inorganic material phase transition, polymer material melting and crystallization process, oil and other food solid/liquid phase ratio
Equipped with standard materials, users can adjust the temperature and enthalpy by themselves
1. Intelligent setting of experimental parameters through software, including temperature program, atmosphere control and sampling Frequency. 2. The instrument automatically switches the gas path system for atmosphere control. 3. Set the heating, cooling or isothermal scanning mode to start the experiment. 4. The instrument automatically collects data, draws in real time, and processes parameters such as enthalpy and Glass transition temperature. 5. After the experiment, use the Baseline deduction function for data processing.
• Operating voltage AC220V/50Hz or custom voltage to avoid power mismatch. • Gas flow rate is controlled at 0~ 200mL/min, gas pressure is 0.2Mpa, to prevent overrun operation. • Check the liquidnitrogen refrigeration system before use to ensure that the semi-automatic pressurization is normal. • Regularly use standard materials for temperature and enthalpy correction to ensure data accuracy. • Avoid operating in high temperature or humid environments to prevent equipment damage. • Pay attention to the atmosphere switching during the experiment to avoid gas leakage. • Sampling Frequency settings need to be adjusted according to experimental needs to ensure data mass.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.