Overview
DAQTECH DT-100 Furnace temperature tracker is a temperature measurement system dedicated to industrial furnaces. It is widely used in the painting and heat treatment industries to map the temperature of metal products in normalizing furnaces, annealing furnaces, nitriding furnaces, tempering furnaces and other processes Linear dispersion. The system allows users to set and optimize the temperature process, regularly monitor the temperature of metal products and workpieces, and do not need to interrupt normal production during key high temperature processes. It can obtain up to 16 points of temperature test Linear dispersion on the surface of the workpiece at a time, and can be equipped with wireless real-time synchronous recording data function.
Features
1. Analysis system advantages include oven temperature setting temperature and transportation speed, time and slope between any two temperature values, maximum temperature and arrival time, horizontal temperature line and vertical time line, test date and time, company name and product name input, data export to Excel, insert picture function, software clear memory data, manual and specified temperature start mode.
2. The advantages of the thermometer include up to 88 Probe types optional, standard voltage calibrating and cold node temperature correction, real-time wireless/wired reception data (optional), intelligent data storage when the instrument is powered off, multiple test storage up to 16 sets of data, USB communication port Quick download and charging, indicator light clear status One-click operation is easy to use.
Principle
The Furnace temperature tracker passes through the industrial furnace heating equipment through the recorder to monitor the process temperature Linear dispersion, using standard voltage calibrated and cold node temperature correction, optional wireless or wired transmission to receive data in real time, the instrument intelligently saves data when power is cut off, and data download and charging through the USB port.
Applications
Painting, heat treatment industry
Standards
Voltage calibrated, temperature calibrated
Steps
1. Set the oven temperature and transportation speed.
2. Select the start mode: button start, delayed start or temperature start.
3. The logger passes through the industrial furnace to obtain temperature Linear dispersion data.
4. Analyze data through software, including time, slope, maximum temperature, etc.
5. Export data to Excel or insert pictures.
6. Use the USB port to download data and charge it.
Notice
• The temperature range of the instrument is 70-80 ° C, and the internal Operating temperature is up to 80 ° C.
• Measurement time with heat box is 35-40 minutes at 300 degrees.
• The battery is a lithium battery, which can last for 50 hours when fully charged.
• Sampling Frequency range is 0.2~ 200.00 seconds.
• Wireless Frequency range from 1.0 to 100.00 seconds.