$ 3488.00Ex works
Adopt equilibrate Conditioning Control system, Temperature range -70 ℃ to + 150 ℃, Humidity 20% -98% RH, with P.I.D automatic calculus control to ensure High Accuracy and Stability, special air circulation system to ensure uniform temperature.
Category : Temperature Humidity Chamber
Brand : AISRY
SKU : NB048588
Service :The delivery and service By NBCLab.Com
NBC-100L-70 programmable constant temperature and humidity tester is a high and low temperature Humidity Cyclic Chamber sold directly by the factory. It is mainly used to test the performance of materials in various environments, and test the heat resistance, cold resistance, dry resistance and moisture resistance performance of various materials. Suitable for mass detection of electronics, electrical appliances, communications, meters, vehicles, plastic products, metals, food, chemicals, building materials, medical, aerospace and other products.
1. The product has beautiful appearance, reasonable structure, precise process, simple and convenient operation and stable and reliable performance. 2. The controller adopts a large-scale color liquid crystal man-machine touch dialog LCD man-machine interface controller, which is easy to operate, easy to learn, stable and reliable. The complete system operation status, execution and setting program Linear dispersion are displayed in both Chinese and English, which can realize RS232 computer interface docking and directly control the instrument remotely through the computer. 3. The refrigeration circulation system adopts the original imported Japanese "Sanyo" brand fully enclosed Compressor (purchased from France Taikang Compressor), and each component adopts imported components, which are from Japan, France, the United States, Italy and other origins. The refrigerant adopts the American environmentally friendly refrigerant (R23A, R404A). 4. The left side of the test Chamber has a test hole with a reserved diameter of 50mm. 5, with fully automatic, high-precision system loop, any part action, with P.L.C locking processing, all using P.I.D automatic calculation control, the whole area temperature with High Accuracy, High Stability. 6, Specially designed air circulation circulation system and sensing system, out of the trend in the return air sensor detection and control, to ensure that the test Chamber Temperature Uniformity, to avoid any dead angle. 7. Adopt enlarged observation window, 4 layers of whole empty tempered Glass, wider field of vision. 8, the instrument has an all-round protection system, power overload protection, leakage protection, control loop overload, short circuit protection, Compressor protection, grounding protection, over-temperature protection, alarm sound prompts, etc. When any abnormal situation occurs, the screen automatically displays the fault point and cause and automatically stops.
The equilibrate Conditioning Control system (BTHC) is adopted, and the induction system transmits the actual data in the test Chamber to the controller. The controller controls the SSR, multi-stage intelligent output, and the output power of the equilibrate temperature Humidity system to ensure that the temperature Humidity in the test Chamber is fully stable and has energy-saving functions. Power is minimized to ensure long-term accurate and stable operation of the instrument.
Electronics, electrical appliances, communications, instrumentation, vehicles, plastic products, metals, food, chemicals, building materials, medical, aerospace
Connect the power supply to ensure that the voltage meets the requirements (220V/50HZ, voltage variation allowable value +/- 10%). 2. Set the required Temperature range (-70 ℃~ + 150 ℃) and Humidity range (20% RH~ 98% RH) through the controller. 3. Start the instrument, monitor the operating status of the system and execute the program Linear dispersion. 4. During the test, the sample status can be observed through the observation window. 5. After the test, turn off the instrument and disconnect the power supply.
• Power supply voltage is checked before use to avoid overload. • Make sure the instrument is well grounded to prevent leakage. • During the operation, pay attention to the controller display, and if there is any abnormal automatic shutdown, deal with the fault in time. • Regularly maintain the refrigeration cycle system to ensure proper operation of the Compressor and Miscellaneous imported components. • Avoid running for a long time at extreme temperatures to prevent overtemperature protection from triggering. • Keep the test Chamber clean to avoid dust affecting the accuracy of the sensing system.
For the high and low temperature humidity testing requirements of electronic products, we recommend the AISRY brand NBC-100L-70 programmable constant temperature and humidity test chamber. This equipment features a wide temperature control range from -70℃ to +150℃ and a humidity control range from 20% to 98% RH. It is suitable for simulating extreme environments that electronic products may encounter, such as severe cold, high temperatures, and high humidity, to test their heat resistance, cold resistance, and moisture resistance, ensuring reliable product quality.
Recommend the AISRY NBC-100L-70. It adopts a Balanced Temperature and Humidity Control System (BTHC) and P.I.D automatic calculation control, ensuring high stability in temperature and humidity regulation (temperature ±0.5-1°C, humidity ±1-2%), which guarantees long-term precise and stable operation. Its inner chamber dimensions are 500*400*550mm, and the overall design is relatively compact (width 1020mm), making it suitable for laboratories with limited space. Additionally, it features a specially designed air circulation system that ensures uniform temperature and humidity distribution inside the chamber, eliminating testing dead zones, making it ideal for precise testing requirements in materials research.
The AISRY NBC-100L-70 is suitable. Its controller features a large color touchscreen LCD display with support for both Chinese and English, making it easy to operate and learn. More importantly, it supports an RS232 interface, allowing for direct remote control and monitoring via a computer, which facilitates data management. In terms of safety, it is equipped with a comprehensive protection system, including safeguards against power overload, leakage, and overheating. In the event of an abnormality, the screen immediately displays the fault point and automatically shuts down, effectively ensuring the safety of the equipment and the testing process.