$ 190.00Ex works
Using catalytic combustion detection principle, the range covers 0-100% LEL, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output, support remote monitoring and linkage control.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048671
Service :The delivery and service By NBCLab.Com
Methane detector GY/VGD-200-CH4-G (0-100% LEL) is a low-power Modular design using MCU chip, with intelligent Sensor detection technology, overall flameproof (d) structure, fixed Installation method detector. Standard configuration is LCDTFT high definition LCD display, three-wire system 4~ 20mA analog, RS485 digital and switching signal output, provide customized products according to user requests, and also support Output signal fine-tuning and other functions, convenient system networking and maintenance.
1. Adopt Customizable Range Intelligent Sensor, which guarantees the advantages of high Sensitivity, high accuracy, linear stability and fast Response of the detector; 2. The use of MCU chip highlights the low power consumption of the detector, safe and reliable performance, accurate data conversion, stable signal output, etc.; 3.4-20mA, RS485, switch and other signal output, easy access to PLC, DCS, DDC and other industrial control systems, can also be a single machine through the switch linkage fan, solenoid valve and other control equipment; 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc.; 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched; 6. The detector can be operated by remote control without opening the lid to perform function menu operations such as alarm value, zero adjustment, calibrating, reset, and modification of the address code; 7. Local integrated sound and light alarm indication, remote mobile phones, computers, monitoring rooms, third-party platforms and other alarm prompts can be realized through alarm control host or wireless signal, and infrared remote control can also be silenced with one click; 8. Aluminum alloy cast body explosion-proof shell, sturdy and durable; 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications; 10. Explosion-proof certificate grade: Ex db IIC T6 Gb; explosion-proof certificate number: SYEx23.04100.
The methane detector adopts the principle of catalytic combustion detection, and detects the gas concentration by the diffusion Sampling method. When the methane gas diffuses to the Sensor, the signal changes under the action of catalytic combustion, which is processed by the MCU chip and converted into electrical signal output.
Flammability Gas detection, industrial safety monitoring, environment monitoring, dangerous place gas alarm
GB/T3836.1-2021 "Explosive environment Part 1: General requirements", GB/T3836.31-2021 "Explosive environment Part 31: Equipment protected by anti-dust ignition enclosure" t ", GB3836.15-2000" Electrical equipment for explosive gas environment Part 15: Electrical installation in hazardous places (except coal mines) ", GB 1 2476.1 - 20 1 3" Electrical equipment for flammability dust environment Part 1: General requirements ", GB12358-2006" General technical requirements for workplace environment Gas detection alarms ", GBZ2.1-2007" Occupational exposure limits for hazardous factors in the workplace ", GB4208-2008" Shell Protection Rating (IP code) "
1. Install the detector in a suitable position to ensure that the Sampling method is diffusion type; 2. Power Supply DC24V (12V~ 30V); 3. Connect the Output signal cable as required (three-core Shielding cable for 4~ 20mA, four-core cable for RS485); 4. Set the alarm value, zero adjustment, calibrating and other parameters through the remote control free opening lid; 5. Start the detector and observe the LCDTFT display to confirm normal operation. 6. Connect external alarm devices or systems as required.
• Working ambient temperature range is -20~ 50 ℃, Humidity range is 10-95% RH (no condensation); • Sensor life is 2 to 3 years, depending on the Operating Environment; • When the connection cable distance exceeds 1000 meters, the diameter of a single wire needs to be ≥ 1.5mm, and the Shielding layer needs to be connected to the earth; • The explosion-proof form is that the Probe transmitter and Sensor are both explosion-proof, and it is necessary to ensure that the installation meets the explosion-proof requirements; • Alarm settings support conventional high and low alarms and interval control alarms, which can be configured according to actual needs; • Optional Accessories such as Power Adapters, converters, etc. need to be additionally configured according to system requirements.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.