Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support a variety of signal output and remote alarm functions, with an overall explosion-proof structure and intelligent Sensor detection technology.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048687
Service :The delivery and service By NBCLab.Com
Chlorine detector GY/VGD-200-CL2-G (0-10ppm) High performance is a low-power Modular design using MCU chip, with intelligent Sensor detection technology, overall flameproof (d) structure, fixed Installation method detector. Standard configuration is LCDTFT high definition LCD display, three-wire system 4~ 20mA analog, RS485 digital and switching signal output, provide customized products according to user requests, and also support Output signal fine-tuning and other functions, convenient system networking and maintenance.
1. Customizable Range Intelligent Sensor, High Sensitivity, High Accuracy, Linear Stability, Fast Response 2. Using MCU chip, low power consumption, safe and reliable performance, accurate data conversion, stable signal output 3. Support 4-20mA, RS485, switch and other signal output, easy access to PLC, DCS, DDC and other industrial control systems 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched 6. The alarm value, zero adjustment, calibrate, reset, modify the address code and other function menu operations can be carried out by remote control without opening the lid 7. Local integrated sound and light alarm indication, support remote mobile phones, computers, monitoring rooms, third-party platforms and other alarm prompts, and can be silenced by infrared remote control with one click 8. Aluminum alloy cast explosion-proof shell, sturdy and durable 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications
The detector adopts the principle of catalytic combustion detection, and detects chlorine concentration by diffusion Sampling method. Sensor converts the detected gas concentration signal into an electrical signal, and outputs a standard signal after processing by MCU chip.
Industrial Gas detection, environment monitoring, safety protection, chemical production, sewage treatment, metallurgy, electric power
GB/T3836.1-2021、GB/T3836.31-2021、GB3836.15-2000、GB12476.1-2013、GB12358-2006、GBZ2.1-2007、GB4208-2008
1. Install the detector and connect the power supply 2. Set the alarm value through the remote control 3. Zero and calibrate operations 4. Modify the address code as needed 5. Connect Output signal to receiving device 6. Start the detector and start working
• Operating voltage range is DC12V~ 30V, DC24V is recommended • Ambient Temperature -20~ 50 ℃ • Environmental humidity of 10-95% RH (non-condensing) Sensor life is 2-3 years depending on Operating Environment • Connecting cable selection: 4~ 20mA choose three-core Shielding cable, RS485 choose four-core • When the transmission distance exceeds 1000 meters, the diameter of a single wire must be ≥ 1.5mm. • Shielding needs to be connected to the earth Explosion-proof level Ex db IIC T6 Gb • Optional 220V to 24V Power Adapter
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.