$ 280.00Ex works
Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds. Support a variety of signal output and wireless transmission, with explosion-proof structure and remote alarm function.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048710
Service :The delivery and service By NBCLab.Com
Hydrogen chloride detector (model GY/VGD-200-HCL-G (0-10ppm)) is a low-power Modular design using MCU chip, with intelligent Sensor detection technology, overall flameproof (d) structure, fixed Installation method detector. Standard configuration is LCDTFT high definition LCD display, three-wire system 4~ 20mA analog, RS485 digital and switching signal output, provide customized products according to user requests, and also support Output signal fine-tuning and other functions to facilitate system networking and maintenance.
1. Adopt Customizable Range Intelligent Sensor, which guarantees the advantages of high Sensitivity, high accuracy, linear stability and fast Response of the detector; 2. The use of MCU chip highlights the low power consumption of the detector, safe and reliable performance, accurate data conversion, stable signal output, etc.; 3.4-20mA, RS485, switch and other signal output, easy access to PLC, DCS, DDC and other industrial control systems, can also be a single machine through the switch linkage fan, solenoid valve and other control equipment; 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc.; 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched; 6. The detector can be operated by remote control without opening the lid to perform function menu operations such as alarm value, zero adjustment, calibrating, reset, and modification of the address code; 7. Local integrated sound and light alarm indication, remote mobile phones, computers, monitoring rooms, third-party platforms and other alarm prompts can be realized through alarm control host or wireless signal, and infrared remote control can also be silenced with one click; 8. Aluminum alloy cast body explosion-proof shell, sturdy and durable; 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications; 10. Explosion-proof certificate grade: Ex db IIC T6 Gb; explosion-proof certificate number: SYEx23.04100.
The hydrogen chloride detector adopts the principle of catalytic combustion detection and detects the gas concentration through the diffusion Sampling method. When the gas diffuses to the Sensor, the catalytic combustion reaction generates a signal, which is processed by the MCU chip and converted into a standard Output signal.
Workplace environment Gas detection, industrial process control, safety monitoring system, electrical installation in dangerous places, dust environment monitoring
GB/T3836.1-2021、GB/T3836.31-2021、GB3836.15-2000、GB12476.1-2013、GB12358-2006、GBZ2.1-2007、GB4208-2008
1. Install the detector to ensure that the electrical interface is connected correctly. 2. Connect the power supply (DC24V, range 12V~ 30V); 3. Set the alarm value, zero adjustment, calibrating and other parameters through the remote control or Operating interface; 4. Start the detector and monitor the gas concentration; 5. Connect Output signal (such as 4-20mA, RS485, switch) to the receiving device as needed; 6. Regularly maintain and calibrate Sensors.
• Operating ambient temperature range is -20~ 50 ℃, Humidity is 10-95% RH (no condensation); • Sensor life is 2 to 3 years, depending on the Operating Environment; • When connecting the cable, choose three-core Shielding cable for 4~ 20mA, four-core for RS485, and when the distance exceeds 1000 meters, the diameter of a single wire is ≥ 1.5mm. Shielding layer needs to be connected to the earth; • Explosion-proof form Probe Transmitter and Sensor are flameproof; • Optional Accessories such as Power Adapter, computer monitoring accessories, the user pays the cost; • Alarm settings support conventional high and low alarms and interval control alarms; • Wireless transmission is optional, pay attention to the module type and transmission distance.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.