$ 719.00Ex works
Modular design with low power consumption using MCU chip, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support 4-20mA, RS485 and switch signal output, easy access to industrial control system linkage control equipment.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048713
Service :The delivery and service By NBCLab.Com
Phosgene detector GY/VGD-200-COCL2-G (0-1.000 ppm) is a low-power Modular design using MCU chip, intelligent Sensor detection technology, overall flameproof (d) structure, fixed Installation method detector. The standard configuration is LCDTFT high definition LCD display, three-wire 4~ 20mA analog, RS485 digital and switching signal output, customized products are provided according to user requests, and Output signal fine-tuning and other functions are also supported, which is convenient for system networking and maintenance.
1. Adopt Customizable Range Intelligent Sensor, which guarantees the advantages of high Sensitivity, high accuracy, linear stability and fast Response of the detector; 2. The use of MCU chip highlights the low power consumption of the detector, safe and reliable performance, accurate data conversion, stable signal output, etc.; 3.4-20mA, RS485, switch and other signal output, easy access to PLC, DCS, DDC and other industrial control systems, can also be a single machine through the switch linkage fan, solenoid valve and other control equipment; 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc.; 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched; 6. The detector can be operated by remote control without opening the lid to perform function menu operations such as alarm value, zero adjustment, calibrating, reset, and modification of the address code; 7. Local integrated sound and light alarm indication, remote mobile phones, computers, monitoring rooms, third-party platforms and other alarm prompts can be realized through alarm control host or wireless signal, and infrared remote control can also be silenced with one click; 8. Aluminum alloy cast body explosion-proof shell, sturdy and durable; 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications; 10. Explosion-proof certificate grade: Ex db IIC T6 Gb; explosion-proof certificate number: SYEx23.04100.
The phosgene detector adopts the principle of catalytic combustion detection, and detects the gas concentration by the diffusion Sampling method. When the gas diffuses to the Sensor, the catalytic combustion reaction generates a signal, which is processed by the MCU chip and converted into accurate data output.
Workplace environment Gas detection, explosive environment, flammability dust environment, electrical installation in hazardous places, occupational exposure limit monitoring of hazardous factors in the workplace
GB/T3836.1-2021、GB/T3836.31-2021、GB3836.15-2000、GB12476.1-2013、GB12358-2006、GBZ2.1-2007、GB4208-2008
1. Install the detector to ensure that the electrical interface is connected correctly. 2. Operating voltage DC24V (12V~ 30V); 3. Carry out function menu operations such as alarm value, zero adjustment, calibrating, reset, and modification of address code through remote control without opening the lid; 4. Connect Output signal (such as 4-20mA, RS485, switch) to the receiving device as needed; 5. Monitor LCDTFT display data and set Alarm mode (regular high and low alarm, interval control alarm); 6. Regularly maintain and calibrate Sensors to ensure detection accuracy.
• Ambient Temperature should be kept in the range of -20~ 50 ℃; • Environmental humidity of 10-95% RH to avoid condensation; • Sensor life is 2~ 3 years, and it is replaced regularly according to the Operating Environment; • When connecting the cable, choose three-core Shielding cable for 4~ 20mA, four-core for RS485, and when the distance exceeds 1000 meters, the single wire diameter is ≥ 1.5mm, and the Shielding layer is connected to the earth; • The explosion-proof form is Probe Transmitter and Sensor are flameproof to ensure safe use in dangerous places; • Alarm settings support two-level alarm, Alarm mode can be adjusted according to needs; • When selecting Accessories such as Power Adapter or Wireless Module, confirm compatibility; • Regularly check electrical interfaces and cable connections to prevent loosening or damage.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.