$ 654.00Ex works
Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support a variety of signal output and wireless transmission, with explosion-proof structure and remote alarm function.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048721
Service :The delivery and service By NBCLab.Com
The hydrogen bromide detector is a low-power Modular design using MCU chip, with intelligent Sensor detection technology, overall flameproof (d) structure, and fixed Installation method. The standard configuration is LCDTFT high definition liquid crystal display, three-wire system 4~ 20mA analog, RS485 digital and switching signal output, and provides customized products according to user requests. Outsignal put fine-tuning and other functions are also supported, which is convenient for system networking and maintenance.
1. Adopt Customizable Range Intelligent Sensor, which guarantees the advantages of high Sensitivity, high accuracy, linear stability and fast Response of the detector; 2. The use of MCU chip highlights the low power consumption of the detector, safe and reliable performance, accurate data conversion, stable signal output, etc.; 3.4-20mA, RS485, switch and other signal output, easy access to PLC, DCS, DDC and other industrial control systems, can also be a single machine through the switch linkage fan, solenoid valve and other control equipment; 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc.; 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched; 6. The detector can be operated by remote control without opening the lid to perform function menu operations such as alarm value, zero adjustment, calibrating, reset, and modification of the address code; 7. Local integrated sound and light alarm indication, remote mobile phones, computers, monitoring rooms, third-party platforms and other alarm prompts can be realized through alarm control host or wireless signal, and infrared remote control can also be silenced with one click; 8. Aluminum alloy cast body explosion-proof shell, sturdy and durable; 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications; 10. Explosion-proof certificate grade: Ex db IIC T6 Gb; explosion-proof certificate number: SYEx23.04100.
The hydrogen bromide detector adopts the principle of catalytic combustion detection and detects the gas concentration by diffusion Sampling method.
Workplace environment Gas detection, industrial process control, safety monitoring system
GB/T3836.1-2021、GB/T3836.31-2021、GB3836.15-2000、GB12476.1-2013、GB12358-2006、GBZ2.1-2007、GB4208-2008
1. Install the detector to ensure that the electrical interface is connected correctly. 2. Connect the power supply, Operating voltage is DC24V (12V~ 30V); 3. Set the alarm value, zero adjustment, calibrate, reset, modify the address code and other functions through the remote control free opening lid; 4. Start the detector and monitor the gas concentration; 5. Connect Output signals to receiving devices such as computers, PLCs, DCS, etc.
• Ambient Temperature should be kept in the range of -20~ 50 ℃; • Environmental humidity should be maintained at 10-95% RH without condensation; • Use a three-core Shielding cable to connect a 4-20mA signal. When the transmission distance exceeds 1000 meters, a single wire diameter needs to be ≥ 1.5mm, and the Shielding layer needs to be connected to the earth; • Sensor life is 2 to 3 years, depending on the Operating Environment; • The explosion-proof form is that the Probe transmitter and Sensor are both explosion-proof, and it is necessary to ensure that the installation meets the explosion-proof requirements; • Optional Accessories such as Power Adapter, computer monitoring accessories, etc., need to be selected according to actual needs.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.