$ 719.00Ex works
MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support 4-20mA and RS485 and other signal output, easy access to industrial control system, with remote control operation and sound and light alarm function.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048724
Service :The delivery and service By NBCLab.Com
GUOYUGRA GY/VGD-200-GeH4-G (0-1.000 ppm) germane detector is a low-power Modular design using MCU chip, intelligent Sensor detection technology, integral flameproof (d) structure, fixed Installation method gas concentration detector. Standard configuration includes LCDTFT high definition LCD display, three-wire 4~ 20mA analog, RS485 digital and switching signal output, support customized products and Output signal fine-tuning function, easy system networking and maintenance.
1. Customizable Range Intelligent Sensor, High Sensitivity, High Accuracy, Linear Stability, Fast Response 2. Using MCU chip, low power consumption, safe and reliable performance, accurate data conversion, stable signal output 3. Support 4-20mA, RS485, switch and other signal output, can be connected to PLC, DCS, DDC and other industrial control systems or linkage control equipment 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched 6. Alarm value, zero adjustment, calibrate, reset, modify address code and other operations can be carried out by remote control without opening the lid 7. Local integrated sound and light alarm, support remote alarm prompt and infrared remote control one-button muffler 8. Aluminum alloy cast explosion-proof shell, sturdy and durable 9. Passed CMA, CNAS, CE, ROHS, SIL, UL, ECM and other international certifications 10. Explosion-proof level Ex db IIC T6 Gb, explosion-proof certificate number SYEx23.04100
The detector adopts the principle of catalytic combustion detection and detects gas concentration by diffusion Sampling method. The intelligent Sensor converts the gas concentration signal into an electrical signal, which is processed by the MCU chip and outputs 4-20mA, RS485, switching signal and other signals to realize gas concentration monitoring and alarm functions.
Industrial Gas detection, environment monitoring, safety protection, chemical production, dangerous place monitoring
GB/T3836.1-2021、GB/T3836.31-2021、GB3836.15-2000、GB12476.1-2013、GB12358-2006、GBZ2.1-2007、GB4208-2008
1. Install the detector to ensure that the electrical interface is connected correctly 2. Connect DC24V Power Supply 3. Set the alarm value, zero adjustment, calibrating and other parameters through the remote control or Operating interface 4. Monitor the gas concentration data displayed on the LCDTFT display 5. Connect PLC, DCS, DDC and other Control systems or linkage equipment as needed 6. Regular maintenance and calibrating operations
• Operating voltage range is DC12V~ 30V, need to ensure stable power supply • Working Ambient Temperature -20~ 50 ℃, Humidity 10-95% RH (non-condensing) • Sensors have a lifespan of 2 to 3 years and need to be replaced regularly according to the Operating Environment • Shielding cable is required for connecting cables. When the distance exceeds 1000 meters, the single wire diameter is ≥ 1.5mm, and the Shielding layer needs to be grounded. • The explosion-proof form is explosion-proof, and the installation and maintenance must meet the explosion-proof requirements • Wireless transmission module is optional and needs to be configured according to actual needs • Alarm settings support conventional high and low alarms and interval control alarms, and the alarm value needs to be set reasonably • Optional Accessories such as Power Adapters and Monitoring Accessories need to be configured on demand
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.