$ 912.00Ex works
Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, with explosion-proof structure and a variety of signal output interfaces, support remote wireless transmission and customized range.
Category : Gas Detector
Brand : GUOYUGR
SKU : NB048732
Service :The delivery and service By NBCLab.Com
Nitrogen trichloride detector is a low-power Modular design using MCU chip, intelligent Sensor detection technology, overall flameproof (d) structure, fixed Installation method detector. The standard configuration is LCDTFT high definition LCD display, three-wire system 4~ 20mA analog, RS485 digital and switching signal output, provide customized products according to user requests, and also support Outsignal put fine-tuning and other functions, which is convenient for system networking and maintenance.
1. Adopt Customizable Range Intelligent Sensor, which guarantees the advantages of high Sensitivity, high accuracy, linear stability and fast Response of the detector; 2. The use of MCU chip highlights the low power consumption of the detector, safe and reliable performance, accurate data conversion, stable signal output, etc.; 3.4-20mA, RS485, switch and other signal output, easy access to PLC, DCS, DDC and other industrial control systems, can also be a single machine through the switch linkage fan, solenoid valve and other control equipment; 4. Support customized wireless signal transmission: Zigbee, LORA, 433M, 4G, WiFi, NB, GPRS, etc.; 5 point array high definition LCDTFT LCD screen, Chinese and English Operating interface can be switched; 6. The detector can be operated by remote control without opening the lid to perform function menu operations such as alarm value, zero adjustment, calibrating, reset, and modification of the address code; 7. Local integrated sound and light alarm indication, remote mobile phones, computers, monitoring rooms, third-party platforms and other alarm prompts can be realized through alarm control host or wireless signal, and infrared remote control can also be silenced with one click; 8. Aluminum alloy cast body explosion-proof shell, sturdy and durable; 9. Passed a variety of CMA, CNAS, CE, ROHS, SIL, UL, ECM safety and other international certifications; 10. Explosion-proof certificate grade: Ex db IIC T6 Gb; explosion-proof certificate number: SYEx23.04100.
The detector adopts the principle of catalytic combustion detection, and detects the gas concentration through the diffusion Sampling method. The detected signal is processed by the MCU chip, and the output is 4~ 20mA analog signal, RS485 digital signal or switching signal, so as to realize the accurate measurement of gas concentration and alarm function.
Workplace environment Gas detection, explosive environment monitoring, flammability dust environment monitoring, industrial process control, safety monitoring system
GB/T3836.1-2021 "Explosive environment Part 1: General requirements", GB/T3836.31-2021 "Explosive environment Part 31: Equipment protected by anti-dust ignition enclosure" t ", GB3836.15-2000" Electrical equipment for explosive gas environment Part 15: Electrical installation in hazardous places (except coal mines) ", GB 1 2476.1 - 20 1 3" Electrical equipment for flammability dust environment Part 1: General requirements ", GB12358-2006" General technical requirements for workplace environment Gas detection alarms ", GBZ2.1-2007" Occupational exposure limits for hazardous factors in the workplace ", GB4208-2008" Shell Protection Rating (IP code) "
1. Install the detector to ensure that the electrical interface is connected correctly. 2. Power Supply (DC24V); 3. Set the alarm value, zero adjustment, calibrating and other parameters through the remote control or Operating interface; 4. The detector starts to work and displays the gas concentration in real time; 5. When the concentration exceeds the set threshold, the sound and light alarm is triggered; 6. Data can be monitored or alarm devices can be controlled through a remote system.
• Operating voltage range is DC12V~ 30V to ensure stable power supply; • Working Ambient Temperature -20~ 50 ℃, Humidity 10-95% RH (non-condensing); Sensors have a lifespan of 2 to 3 years and require regular calibration and maintenance. • When connecting the cable, choose three-core Shielding cable for 4~ 20mA, four-core for RS485, and when the distance exceeds 1000 meters, the single wire diameter is ≥ 1.5mm, and the Shielding layer is connected to the earth; • The explosion-proof form is explosion-proof, and the installation must meet the explosion-proof requirements; • Alarm settings support conventional high and low alarms and interval control alarms, which need to be reasonably configured; • Optional Accessories such as Power Adapters or wireless modules need to be selected according to actual needs.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.